6-9
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
78-19416-01
Chapter 6 Manage Circuits
Before You Begin
Note
It is not necessary to set the format (16 or 64 bytes) for the circuit destination expected
string; the path trace process automatically determines the format.
Step 10
Provision the circuit source expected string:
a.
In the Edit Circuit window (with Show Detailed Map chosen), right-click the circuit source port and
choose
Edit Path Trace
from the shortcut menu.
b.
In the Circuit Path Trace window, enable the path trace expected string by choosing
Auto
or
Manual
from the Path Trace Mode drop-down list:
•
Auto—Uses the first string received from the port at the other path trace end as the baseline
string. An alarm is raised when a string that differs from the baseline is received.
•
Manual—Uses the Current Expected String field as the baseline string. An alarm is raised when
a string that differs from the Current Expected String is received.
c.
If you set the Path Trace Mode field to Manual, enter the string that the circuit source should receive
from the circuit destination in the New Expected String field. If you set Path Trace Mode to Auto,
skip this step.
d.
(Check box visibility depends on card selection) Click the
Disable AIS on C2 Mis-Match
check
box if you want to suppress the Alarm Indication Signal when a C2 mismatch occurs.
e.
Click
Apply
.
Note
It is not necessary to set the format (16 or 64 bytes) for the circuit source expected string;
the path trace process automatically determines the format.
Step 11
After you set up the path trace, the received string appears in the Received field on the path trace setup
window. The following options are available:
•
Click
Hex Mode
to display path trace in hexadecimal format. The button name changes to ASCII
Mode. Click it to return the path trace to ASCII format.
•
Click the
Reset
button to reread values from the port.
•
Click
Default
to return to the path trace default settings (Path Trace Mode is set to Off and the New
Transmit and New Expected Strings are null).
Caution
Clicking Default will generate alarms if the port on the other end is provisioned with a different string.
The expect and receive strings are updated every few seconds if the Path Trace Mode field is set to Auto
or Manual.
Step 12
Click
Close
.
The detailed circuit window indicates path trace with an M (manual path trace) or an A (automatic path
trace) at the circuit source and destination ports.
Stop. You have completed this procedure.
Содержание ONS 15310-MA SDH
Страница 20: ...Figures xx Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 ...
Страница 45: ...xlv Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Страница 48: ...xlviii Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Страница 290: ...15 4 Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Chapter 15 Power Down the Node ...