16-8
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
78-19416-01
Chapter 16 DLPs H1 to H99
Figure 16-5
Crimping Tool
Step 8
Close the tool until the ratchet releases.
shows the terminal crimped to the power cable.
Figure 16-6
Terminal Connector Crimped to the Power Cable
Step 9
Carefully remove the crimped terminal.
Step 10
Insert crimped terminal into outside holes of the supplied 3-pin receptacle. Leave the center hole empty.
The D-shaped terminal is for BAT (–48V). The O-shaped terminal on the other side of the connector is
for RET.
Note
This power cable is suitable for maximum 5A, 60 VDC.
Note
The DC power Battery Return (BR) or positive terminal, must be grounded at the source end
(power feed or DC mains power end). The DC power BR input terminal of the ONS 15xxx is not
connected to the equipment frame (chassis).
Step 11
Plug the DC power connector into either plug on the rear of the chassis at the outside corners of the
ONS 15310-MA SDH.
Wire
Insulation
grips
Conductor
grips
Terminal
Locator
124935
124683