16-103
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
78-19416-01
Chapter 16 DLPs H1 to H99
Step 3
If you want alarm filtering enabled when you view conditions, repeat Steps
using the Conditions
window.
Step 4
If you want alarm filtering enabled when you view alarm history, repeat Steps
using the History
window.
Step 5
Return to your originating procedure (NTP).
DLP-H85 Modify Alarm and Condition Filtering Parameters
Step 1
At the node, network, or card view, click the
Alarms
tab,
Conditions
tab, or
History
tab.
Step 2
Click the
Filter
command button at the lower-left of the bottom toolbar.
The filter dialog box appears, displaying the General tab.
shows the Alarm Filter dialog
box; the Conditions and History tabs have similar dialog boxes.
Figure 16-23
Alarm Filter Dialog Box General Tab
In the General tab Show Severity box, you can choose which alarm severities will show through the
alarm filter and provision a time period during which filtered alarms show through the filter. To change
the alarm severities shown in the filter, go to
. To change the time period filter for the alarms go
to
Purpose
This task changes alarm and condition reporting in all network nodes.
Tools/Equipment
None
Prerequisite Procedures
DLP-H84 Enable Alarm Filtering, page 16-102
DLP-H29 Log into CTC, page 16-43
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Retrieve or higher
Содержание ONS 15310-MA SDH
Страница 20: ...Figures xx Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 ...
Страница 45: ...xlv Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Страница 48: ...xlviii Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Страница 290: ...15 4 Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Chapter 15 Power Down the Node ...