17-68
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
78-19416-01
Chapter 17 DLPs H100 to H199
DLP-H177 Manual or Force Switch the Node Timing Reference
Step 1
In node view, click the
Maintenance
>
Timing
>
Source
tabs. The Timing Source window appears.
Step 2
Click the Reference drop-down list for the desired Clock, and choose the desired reference.
Step 3
Click the Operation drop-down list for the desired Clock, and choose one of the following options:
•
Manual
—This operation commands the NE to switch to the reference you have selected, if the SSM
quality of the reference is not less than the quality of the reference that the node is currently running.
•
Force
—This operation commands the NE to switch to the reference you have selected, regardless
of the SSM quality, if the reference is valid.
Step 4
Click
Apply
.
Step 5
Click
Yes
in the confirmation dialog box.
•
If the selected timing reference is invalid, a warning dialog appears. Click
OK
; the NE remains on
the original timing reference without performing the switch.
•
If the selected timing reference is an acceptable valid reference, the NE switches to the selected
timing reference.
Step 6
Return to your originating procedure (NTP).
DLP-H178 Clear a Manual or Force Switched Node Timing Reference
Step 1
In node view, click the
Maintenance
>
Timing
>
Source
tabs. The Timing Source window appears.
Step 2
Find the Clock reference that is currently set to Manual or Force in the Operation drop-down list.
Step 3
Click the Operation drop-down list for the clock and choose
Clear
.
Purpose
This task commands the node to switch to the timing reference that you
have selected if the synchronization status message (SSM) quality of the
reference is not less than the quality of the reference that the node is
currently running.
Tools/Equipment
None
Prerequisite Procedures
DLP-H29 Log into CTC, page 16-43
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Maintenance or higher
Purpose
This task clears a Manual or Force switch on a node timing reference and
reverts the timing reference to its provisioned reference.
Tools/Equipment
None
Prerequisite Procedures
DLP-H29 Log into CTC, page 16-43
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Maintenance or higher
Содержание ONS 15310-MA SDH
Страница 20: ...Figures xx Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 ...
Страница 45: ...xlv Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Страница 48: ...xlviii Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Страница 290: ...15 4 Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Chapter 15 Power Down the Node ...