17-46
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
78-19416-01
Chapter 17 DLPs H100 to H199
•
Cannot Change New Password for [ ] days—If checked, prevents users from changing their
password for the specified period. The range is 20 to 95 days.
•
Require Password Change on First Login to New Account—If checked, requires users to change his
or her password the first time they log into the account.
Step 7
To require users to change their password at periodic intervals, check the Enforce Password Aging check
box in the Password Aging area. If checked, provision the following parameters:
•
Aging Period—Sets the amount of time that must pass before the user must change his or her
password for each security level: RETRIEVE, MAINTENANCE, PROVISIONER, SUPERUSER.
The range is 20 to 95 days.
•
Warning—Sets the number days the user will be warned to change his or her password for each
security level. The range is 2 to 20 days.
Step 8
In the Other area, you can provision the following:
•
Single Session Per User
—
If checked, limits users to one login session at one time.
•
Disable Inactive User—If checked, disables users who do not log into the node for the period of time
specified in the Inactive Duration box. The Inactive Duration range is 45 to 90 days.
Step 9
In the Select Applicable Nodes area, uncheck any nodes where you do not want to apply the changes.
Step 10
Click
OK
.
Step 11
In the Security Policy Change Results dialog box, confirm that the changes are correct, then click
OK
.
Step 12
Return to your originating procedure (NTP).
DLP-H143 Change Node Access and PM Clearing Privilege
Step 1
In node view, click the
Provisioning
>
Security > Access
tabs.
Step 2
In the Access area, provision the following:
•
LAN access—Choose one of the following options to set the access paths to the node:
–
No LAN Access
—Allows access to the node only through data communications channel (DCC)
connections. Access through the CTX-2500 RJ-45 port and backplane is not permitted.
–
Front only
—Allows access through the CTX-2500 RJ-45 port. Access through the DCC and
the backplane is not permitted.
–
Backplane only
—Allows access through DCC connections and the backplane. Access through
the CTX-2500 RJ-45 port is not allowed.
Purpose
This task provisions the physical access points and shell programs used to
connect to the ONS 15310-MA SDH and sets the user security level that
can clear node performance monitoring data.
Tools/Equipment
None
Prerequisite Procedures
DLP-H29 Log into CTC, page 16-43
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Superuser only
Содержание ONS 15310-MA SDH
Страница 20: ...Figures xx Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 ...
Страница 45: ...xlv Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Страница 48: ...xlviii Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Страница 290: ...15 4 Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Chapter 15 Power Down the Node ...