Chapter 16 DLPs H1 to H99
DLP-H49 Create a Provisionable Patchcord
Note
To set up a provisionable patchcord between an optical port and an ONS node transponder/muxponder,
an add/drop multiplexer, or multiplexer/demultiplexer port, the optical port must have an
RS-DCC/MS-DCC termination provisioned. If the port is the protection port in a 1+1 group, the working
port must have an RS-DCC/MS-DCC termination provisioned. As needed, complete the
Provision Section DCC Terminations” task on page 16-68
Note
An optical port requires two patchcords when the remote end is Y-cable protected or is an add/drop
multiplexer or multiplexer/demultiplexer port.
Step 1
In node view, click the
Provisioning > Comm Channels > PPCs
tabs. If you are in network view, click
the
Provisioning >
Provisionable Patchcords (PPC)
tabs.
Step 2
Click
Create
. The Provisionable Patchcord dialog box appears.
Step 3
In the Origination Node area, complete the following:
a.
If you are in node view, the Origination Node defaults to the current node. If you are in network
view, click the desired origination node from the drop-down list.
b.
Type a patchcord identifier (0 through 32767) in the TX/RX ID field.
c.
Click the desired origination slot/port from the list of available slots/ports.
Step 4
In the Termination Node area, complete the following:
a.
Click the desired termination node from the drop-down list. If the remote node has not previously
been discovered by CTC but is accessible by CTC, type the name of the remote node.
b.
Type a patchcord identifier (0 through 32767) in the TX/RX ID field. The origination and
termination IDs must be different if the patchcord is set up between two cards on the same node.
c.
Click the desired termination slot/port from the list of available slots/ports. The origination port and
the termination port must be different.
Step 5
If you need to provision Tx and Rx separately for multiplexer/demultiplexer cards, check the
Separate
Tx/Rx
check box. If not, continue with
. The origination and termination TX ports are already
provisioned. Complete the following to provision the RX ports:
a.
In the Origination Node area, type a patchcord identifier (0 through 32767) in the RX ID field. The
origination Tx and Rx and termination Tx and Rx IDs must be different.
Purpose
This task creates a provisionable patchcord, also called a virtual link.
Patchcords are used for network communication when a DCC/GCC is not
available. They appear as dashed lines in CTC network view.
For the specific situations in which a patchcord is necessary, refer to the
Cisco ONS 15310-MA SDH Reference Manual
.
Tools/Equipment
For for information about patchcords, refer to the
Cisco ONS 15310-MA
SDH Reference Manual
.
Prerequisite Procedures
DLP-H29 Log into CTC, page 16-43
Required/As Needed
As needed
Onsite/Remote
Onsite or remote
Security Level
Provisioning or higher
Содержание ONS 15310-MA SDH
Страница 20: ...Figures xx Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 ...
Страница 45: ...xlv Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Страница 48: ...xlviii Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Страница 290: ...15 4 Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Chapter 15 Power Down the Node ...