C H A P T E R
15-1
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
78-19416-01
15
Power Down the Node
This chapter explains how to power down a Cisco ONS 15310-MA SDH node and stop all node activity.
NTP-H120 Power Down the ONS 15310-MA SDH
Caution
The following procedure is designed to minimize traffic outages when powering down nodes, but traffic
will be lost if you delete and recreate circuits that passed through a working node.
Caution
Always use the supplied ESD wristband when working with the ONS 15310-MA SDH. For detailed
instructions on how to wear the ESD wristband, refer to the
Cisco ONS Electrostatic Discharge (ESD)
.
Step 1
Identify the node that you want to power down. If no cards are installed, go to Step
. If a card is
installed, log into the node. See the
“DLP-H29 Log into CTC” task on page 16-43
for instructions.
Step 2
In node view, choose
Go to Network view
from the View menu.
Step 3
Verify that the node is not connected to a network.
a.
If the node is part of a working network, log out of the node and complete the
a Path Protection Node” procedure on page 13-4
or the
“NTP-H101 Remove an In-Service Node
from a Linear ADM” procedure on page 13-9
. Continue with
b.
If the node is not connected to a working network and the current configurations are no longer
required, continue with
.
Purpose
This procedure stops all node activity.
Tools/Equipment
None
Prerequisite Procedures
None
Required/As Needed
As needed
Onsite/Remote
Onsite
Security Level
For software steps, the Provisioning level or higher is required. For
hardware steps, any level is allowed.
Содержание ONS 15310-MA SDH
Страница 20: ...Figures xx Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 ...
Страница 45: ...xlv Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Страница 48: ...xlviii Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Страница 290: ...15 4 Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Chapter 15 Power Down the Node ...