1-10
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
78-19416-01
Chapter 1 Install the Cisco ONS 15310-MA SDH
Required Tools and Equipment
Step 3
If you plan to install electrical interface assemblies (EIAs), continue with the
. If not, continue with the
“NTP-H151 Install the Power and Ground”
Stop. You have completed this procedure.
NTP-H167 Install the EIAs
Caution
Connect only SELV services to the high-density EIAs on the ONS 15310-MA SDH.
Step 1
Determine which high-density EIA is designed for installation on the B Side and which is designed for
installation on the A Side (
For both OSP and non-OSP installations on the ONS 15310-MA SDH, following ONS 15310-MA SDH
EIAs must be installed:
•
15310E-EIA-HDA=, PN 800-29917-01
•
15310E-EIA-HDB=, PN 800-29918-01
Note
For information about OSP installation, refer to the installation manual provided with the OSP
cabinet.
Purpose
This procedure describes how to install electrical interface assemblies
(EIAs).
Tools/Equipment
#2 Phillips screwdriver
High-density EIAs
6-32 x 5/16-inch pan head screws (3, included with EIA)
Prerequisite Procedures
NTP-H169 Install the Cable Management Bracket, page 1-6
Required/As Needed
As needed
Onsite/Remote
Onsite
Security Level
None
Содержание ONS 15310-MA SDH
Страница 20: ...Figures xx Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 ...
Страница 45: ...xlv Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Страница 48: ...xlviii Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Preface ...
Страница 290: ...15 4 Cisco ONS 15310 MA SDH Procedure Guide Release 9 1 and Release 9 2 78 19416 01 Chapter 15 Power Down the Node ...