A-5
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
OL-13208-11
Appendix A Cisco ASR 1000 Series Router Specifications
Cisco ASR 1004 Router Specifications
closed pin. The connections that describe alarm activity are Alarm off (Common is connected to
normally closed and normally open is disconnected) and Alarm on (Common is connected to normally
open and normally closed is disconnected).
Table A-8
lists the common, normally open, and normally closed relay contacts accessible to an external
alarm monitoring facility by means of the DB-25 connector.
Cisco ASR 1004 Router Specifications
This section lists the specifications for the Cisco ASR 1004 Router.
Table A-9
lists the Cisco ASR 1004 Router physical specifications.
Table A-8
Cisco ASR 1006 Router DB-25 Alarm Connector Pinout Assignments
Signal
Description
Common
(CM)
Normally
Open (NO)
Normally
Closed (NC)
SPARE
CRTAA
Critical Audible Alarm
2
1
14
—
MAJAA
Major Audible Alarm
16
3
15
—
MINAA
Minor Audible Alarm
5
4
17
—
CRTVA
Critical Visual Alarm
19
6
18
—
MAJVA
Major Visual Alarm
8
7
20
—
MINVA
Minor Visual Alarm
22
9
21
—
SPARE
SPARE—unused pin
reserved for future use
—
—
—
10, 11, 12, 13,
23, 24, 25
Table A-9
Cisco ASR 1004 Router Specifications
Description
Specification
Midplane
Connects the Cisco ASR 1000 Series RP1, ASR 1000 Series ESP, Cisco ASR 1000 Series
SPA Interface (SIP), SPAs, and power supplies together in the system
Dimensions (H x W x D)
Height = 7 in. (17.8 cm) (4RU rack-mount per EIA RS-310)
Width = 17.25 in. (43.815 cm) (19 inch rack-mount or optional 23 Telco rack- mount)
Depth = 22.50 in. (57.15 cm) (including card handles, cable-management brackets and
power supply handles)
Weight
•
Fully loaded chassis: 50 pounds (22.6796 kg)
•
Only chassis: 18 pounds (8.16 kg)
Nominal operating temperature
•
41° to 104° F
•
5° to 40° C
Nominal operating humidity
10% to 85%