14-88
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
OL-13208-11
Chapter 14 Removing and Replacing FRUs from the Cisco ASR 1000 Series Routers
Removing and Replacing the Cisco ASR 1002 Router Power Supplies
Step 4
Figure 14-62
shows the wire strip and insulation location.
Figure 14-62
Wire Strip and Lead for the +24 VDC Terminal Block
Step 5
Using a 3.5mm screwdriver, insert the screwdriver at an angle to release the spring while you install the
stripped lead wire (see
Figure 14-63
).
Figure 14-63
Inserting a Screwdriver into the +24 VDC Power Supply Terminal Block
Step 6
Carefully push the screwdriver at an angle forward until you relieve the spring contact.
Step 7
With the screwdriver still inserted, gently push the lead wire (ground lead first) in until there is no copper
wire showing as shown in
Figure 14-64
.
Caution
Check that there is no copper portion of the lead wire exposed. Only wire insulation must be visible.
Caution
Do not install wire into the terminal block that has not had its insulation removed.
1
Lead wire stripped area
—
—
57019
1
253166
OUTPUT
INPUT
FAIL
OK
OK
FAN
This unit might ha
ve more than
one po
wer supply connection.
All connections m
ust be remo
ved
to de-energiz
e the unit.
+27V DC INPUT
+27V 32A