10-39
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation Guide
OL-13208-11
Chapter 10 Cisco ASR 1002-X Router Overview and Installation
Cisco ASR 1002-X Router Power Supplies
Step 4
Using a 3.5mm screwdriver, insert the screwdriver at an angle to release the spring while you install the
stripped lead wire as shown in
Figure 10-27
.
Figure 10-27
Inserting a Screwdriver Into the +24 VDC Power Supply Terminal Block
Step 5
Carefully push the screwdriver at a forward angle until you relieve the spring contact.
Step 6
With the screwdriver still inserted, gently push the lead wire (ground lead first) in until the copper wire,
as shown in
Figure 10-28
, is no longer visible (see
Figure 10-29
).
Caution
Ensure that no copper portion of the lead wire is exposed. Only the wire insulation should visible.
Caution
Do not install wire into a terminal block that has not had its insulation removed.
Figure 10-28
Cisco ASR 1002-X 24 VDC Power Supply Lead Wire Inserted into Terminal
Block
253166
OUTPUT
INPUT
FAIL
OK
OK
FAN
This unit might ha
ve more than
one po
wer supply connection.
All connections m
ust be remo
ved
to de-energiz
e the unit.
+27V DC INPUT
+27V 32A
1
Lead wire insulation
2
Copper wire
253167
OUTPUT
INPUT
FAIL
OK
OK
FAN
This unit might ha
ve more than
one po
wer supply connection.
All connections m
ust be remo
ved
to de-energiz
e the unit.
+27V DC INPUT
+27V 32A
1
2