Connecting Power to the Cisco ASR 1002-F Router
To connect the DC power supply, follow these steps:
Step 1
At the rear of the router, check that the power supply Standby switch is in the Standby position (see
Figure 9-28
).
Figure 9-28
Cisco ASR 1002-F Router DC Power Supply Terminal Block Cable Connections
Step 2
Ensure that the negative and positive leads are disconnected from the site power source.
Step 3
Using a wire stripper, strip approximately 0.55 inch (14 mm) from the negative, positive, and ground
leads.
Step 4
Insert the stripped end of the ground lead all the way into the ground lead receptacle on the DC input
power supply, and tighten the receptacle screw using a 3.5 mm flat-blade screwdriver to a torque of 0.5
to 0.6Nm.
Step 5
Insert the stripped end of the positive lead all the way into the positive lead receptacle and tighten the
receptacle screw using the same 3.5 mm flat-blade screwdriver. Repeat this step for the negative lead.
Note
Make sure the entire stripped end of each lead is inserted all the way into its receptacle. If any
exposed wire at the stripped end of a lead is visible after inserting the lead into its receptacle,
remove the lead from the receptacle, use the wire stripper to cut the stripped end of the lead, and
repeat Step 3 through Step 5.
1
Ground lead with service loop and cable tie
3
Negative lead wire
2
Positive lead wire
4
DC power supply Standby switch
OUTPUT INPUT
FAIL
OK
OK
FAN
-48V/-60V 16A
This unit might h
ave more than
one power supp
ly connection.
All connections m
ust be removed
to de-energize
the unit.
3
1
2
280290
4