72
of Max. grid voltage
GridVminRecT(V)
Recovery threshold value
of Min. grid voltage
{0, 362.6, 480.0}
GridVRecT(S)
Recovery time of grid
voltage protection
{0, 300.00, 600.00}
GridF.Max1(Hz)
Protection threshold value
of Level 1 Max. grid
frequency
{50.00,51.50, 65.00}
FmaxTripT1(S)
Trip time of Level 1 Max.
grid frequency
{0, 0.10, 600.00}
GridF.Min1(Hz)
Protection threshold value
of Level 1 Min. grid
frequency
{45.00, 47.5, 60.00}
FminTripT1(S)
Trip time of Level 1 Min.
grid frequency
{0, 0.10, 600.00}
GridF.Max2(Hz)
Protection threshold value
of Level 2 Max. grid
frequency
{50.00, 51.50, 65.00}
FmaxTripT2(S
)
Trip time of Level 2 Max.
grid frequency
{0, 0.10, 600.00}
GridF.Min2(Hz)
Protection threshold value
of Level 2 Min. grid
frequency
{45.00, 47.50, 60.00}
FminTripT2(S)
Trip time of Level 2 Min.
grid frequency
{0, 0.10, 600.00}
GridFmaxRecT(Hz)
Recovery threshold value
of Max. grid frequency
{49.00, 50.05, 65.00}