31
Figure 3-22 Polarity check
(d) Put the positive (negative) DC cable through the gland and cable
fastener, and then crimp the cable with the cord end terminals shown
in Table 3-6.
Table 3-6 Cord end terminals for DC cables
No.
Item
Function
1
For Positive DC cable
2
For Negative DC cable
(e) Insert the crimped positive and negative terminals into the male and
female housing respectively, and then tighten the seal glands, as
shown in Figure 3-23 and Figure 3-24:
NOTICE:
It is required to use the attached or the same type of DC input
connectors. Otherwise, poor contact may happen, causing problem
of normal use.
Содержание CPS SCA20KTL-DO
Страница 1: ...CPS SCA Series Grid tied PV Inverter CPS SCA20 25KTL DO Installation and Operation Manual Ver 1 0 ...
Страница 18: ...14 3 2 Mechanical installation 1 Dimensions Figure 3 2 Dimensions of CPS SCA20 25KTL DO series inverter ...
Страница 56: ...52 Figure 3 48 The ZigBee cable connection a b c d e ...
Страница 97: ...93 1 5 2 4 3 ...
Страница 98: ...94 Figure 7 1 Replace cooling fans 50 60mm mm 50 60mm mm 6 ...