37
3) The AC output (L1/L2/L3/N) cables of the PV inverter are connected to
the AC grid through the 4 pole AC breaker to make sure the inverter can be
safely disconnected from the AC grid. Please choose the AC breaker referring
to Table 3-9:
Table 3-9 Specification of AC breaker selection
Inverter
AC breaker rated current
(
A
)
CPS SCA20KTL-DO
50
CPS SCA25KTL-DO
64
INSTRUCTION:
The attached pre-insulated end ferrules match with the 10 mm
2
cables. If the cable of other gauge is selected, different pre-insulated
end ferrule is needed and provided by the installers.
Содержание CPS SCA20KTL-DO
Страница 1: ...CPS SCA Series Grid tied PV Inverter CPS SCA20 25KTL DO Installation and Operation Manual Ver 1 0 ...
Страница 18: ...14 3 2 Mechanical installation 1 Dimensions Figure 3 2 Dimensions of CPS SCA20 25KTL DO series inverter ...
Страница 56: ...52 Figure 3 48 The ZigBee cable connection a b c d e ...
Страница 97: ...93 1 5 2 4 3 ...
Страница 98: ...94 Figure 7 1 Replace cooling fans 50 60mm mm 50 60mm mm 6 ...