![Ceyear 1465 Series Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/ceyear/1465-series/1465-series_programming-manual_2584913073.webp)
3 SCPI
3.3 Instrument subsystem command
66
Query current PRF staggered points.
Reset status:
0
Key Entry:
None
Note:
for query only.
[:SOURce]:PULM:INTernal:STAGger:DELete <Index>
Function:
This command is used for deleting any index in Stagg Listof the signal generator. If the
index point to be deleted exceeds the range of list points, this operation will be invalid.
In this case, user may query the current list points before deletion operation. It should
be noted that, if the queried staggered point number is 1, for valid deletion, the index
shall be set to zero. For points in Stagg List, see the command
―
PULM:INTernal:STAGger:POINts
‖.
Setting format:
[:SOURce]:PULM:INTernal:STAGger:DELete <num>
Parameter:
<Index> Index of Stagg List.
Range: 0[0
,
4].
Example:
[:SOURce]:PULM:INTernal:STAGger:DELete 1 Delete the point with index 1 in the
current Stagg List.
Reset status:
0
Key Entry:
【
PULSE
】
—>[Staggered]—>[EditStagg List…] —>[Del Current]
Note:
for setting only.
[:SOURce]:PULM:INTernal:STAGger:PRESet
Function:
This command is used for deleting all points in Stagg List. If there is no staggered point in
current list, this operation will be invalid. In this case, user may query the staggered
points in the current list before deletion operation. For querying points in Stagg List,
see the command ―
PULM:INTernal:STAGger:POINts
‖.
Setting format:
[:SOURce]:PULM:INTernal:STAGger:PRESet
Example:
[:SOURce]:PULM:INTernal:STAGger:PRESet Delete all points in Stagg List.
Key Entry:
【
PULSE
】
—>[Staggered]—>[EditStagg List…] —>[Del All]
Note:
for setting only.
[:SOURce]:PULM:LFM:BWIDth <LfmBwidth>
Function:
This command is used for setting LFM bandwidth. After setting, the output signal centers
on the output carrier frequency of the signal generator, with the FM range equal to
carrier frequency ± 1/2 bandwidth.
Setting format:
[:SOURce]:PULM:LFM:BWIDth <val><freq unit>
Query format:
[:SOURce]:PULM:LFM:BWIDth?
Parameter:
<LfmBwidth> LFM bandwidth.
Range: 4MHz[0Hz
,
200MHz].
Example:
[:SOURce]:PULM:LFM:BWIDth 20MHz LFM bandwidth is 20MHz.