EXTernal Ext, the trigger signal is from the trigger input connector on the rear panel.
KEY |Trigger key; trigger source comes from the trigger key of the front panel.
Example:
:SWEep: TRIGger:SOURce BUS Set Step Trig to Bus mode.
Reset status:
IMM
Key Entry:
【
Sweep
】
—>[Step Sweep]—>[Step Trig]
3.3.7 PULM subsystem
PULM subsystem commands are used for controlling the pulse modulation functions of RF output signal.
The commands and parameters of the subsystem are:
The following commands are used for setting pulse modulation mode:
[:SOURce]:PULM:EXTernal:POLarity ................................................................. 58
[:SOURce]:PULM:INTernal:DELay ..................................................................... 59
[:SOURce]:PULM:INTernal:FREQuency ............................................................ 60
[:SOURce]:PULM:INTernal:PERiod .................................................................... 60
[:SOURce]:PULM:INTernal:PWIDth .................................................................... 61
[:SOURce]:PULM:SOURce ................................................................................. 61
[:SOURce]:PULM:STATe .................................................................................... 62
[:SOURce]:PULM:INTernal:JITTered:MODE ...................................................... 62
[:SOURce]:PULM:INTernal:JITTered:PERCent ................................................. 62
[:SOURce]:PULM:INTernal:PTRain:DATA ......................................................... 63
[:SOURce]:PULM:INTernal:PTRain:DELete ....................................................... 63
[:SOURce]:PULM:INTernal:PTRain:POINts ....................................................... 64
[:SOURce]:PULM:INTernal:PTRain:PRESet ...................................................... 64
[:SOURce]:PULM:INTernal:SLIDing:STEP ......................................................... 64
[:SOURce]:PULM:INTernal:SLIDing:POINts ...................................................... 65
[:SOURce]:PULM:INTernal:STAGger:INSert ...................................................... 65
[:SOURce]:PULM:INTernal:STAGger:POINts .................................................... 65
[:SOURce]:PULM:INTernal:STAGger:DELete .................................................... 66
[:SOURce]:PULM:INTernal:STAGger:PRESet ................................................... 66
[:SOURce]:PULM:LFM:BWIDth .......................................................................... 66
[:SOURce]:PULM:LFM:DIRection ....................................................................... 67
[:SOURce]:PULM:LFM:STATe ............................................................................ 67
[:SOURce]:PULM:EXTernal:POLarity <Mode>
Function:
The command logically inverts the external input pulse signal, i.e. when Pulse Source is
EXT, the pulse signal input from pulse input port on the front panel of the signal
generator is TTL high level signal or is inverted to TTL low level signal. For selecting
pulse source, see the command ―
:PULM:SOURce
‖.
Setting format:
[:SOURce]:PULM:EXTernal:POLarity INVerted|NORMal
Query format:
[:SOURce]:PULM:EXTernal:POLarity?
Parameter:
<Mode> Discrete data. Input Direction is as follows: