3 SCPI
3.3 Instrument subsystem command
104
[:SOURce]:RADio:ARB:TRIGger:TYPE:CONTinuous[:TYPE] <Mode>
Function:
This command sets the mode in which sequence file responds to trigger signal when
ARB is in Continue or Single mode. There are three modes for selection, FREE,
TRIGger
and
RESet.
For
setting
Trig
Mode,
see
the
command
―
:RADio:ARB:TRIGger:TYPE
‖.
Setting format:
[:SOURce]:RADio:ARB:TRIGger:TYPE:CONTinuous
FREE|TRIGger|RESet
Query format:
[:SOURce]:RADio:ARB:TRIGger:TYPE:CONTinuous?
Parameter:
<Mode> Discrete data. The mode in which sequence file responds to trigger signal when ARB is in
Continue mode,
The values are as follows:
FREE
| 0: When Auto mode is selected, sequence is triggered
automatically to start playing after sequence waveform data is
downloaded. All trigger events are ignored during playback
TRIGger
| 1: When Trig mode is selected, no current waveform
sequence will be played until a valid trigger event is received.
After a valid trigger event is received, the system starts to play
the current waveform sequence. After the sequence is played,
no current waveform sequence is replayed until a valid trigger
event occurs
RESet
| 2: When Realtime mode is selected, no modulation source
data will be generated until a valid trigger event is received,
with no code pattern signal generated; after a valid trigger
event is received, the system starts to generate the selected
modulation source data, thereby generating corresponding
code pattern data and signals. After the current source data is
generated, the system will automatically restart to generate the
currently set modulation source data. During the generation
process of modulation source data, if a valid trigger event is
received, the system will immediately abort the modulation
source data currently being generated and restart to generate
the set modulation source data
Example:
[:SOURce]:RADio:ARB:TRIGger:TYPE:CONTinuous TRIG
When ARB is in Continue mode, set the mode in which sequence file responds to trigger signal to
Trig.
Reset status:
FREE
Key Entry:
【
Arb
】
—>[Trigger]—>[Trig Mode]—>[Continue]
[:SOURce]:RADio:ARB:TRIGger:TYPE:SINGle <Mode>
Function:
This command sets the mode in which sequence file responds to trigger signal when
ARB is in Single mode. There are three modes for selection, FREE, TRIGger and