![Ceyear 1465 Series Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/ceyear/1465-series/1465-series_programming-manual_2584913014.webp)
2
Remote Control
2.1 Remote control basis
7
— Query command: query and return data, for example: identify instrument or query parameter
values. The query command is always ended with a question mark.
Based on the definition in the standard:
— Common command: with functions and syntax defined in IEEE488.2, applicable to all
types of instrument (if implemented) for management of standard status register, reset,
self-test, etc.
— Instrument control command: Instrument characteristic command for instrument functions.
For example: set the frequency.
The syntax also follows SCPI specification.
b) Instrument response:
The instrument response (response message and service request) is the query result information sent
by the instrument to the computer. This information includes measurement result and instrument status.
2.1.3 SCPI
Brief introduction to SCPI ...................................................................................................... 6
SCPI description ................................................................................................................. 7
2.1.3.1 Brief introduction to SCPI
SCPI (Standard Commands for Programmable Instruments) is a set of commands established for all
instruments based on IEEE488.2 mainly to achieve the universality of SCPI, i.e.the same SCPI is
generated and issued for the same function.
The SCPI consists of a command header and one or more parameters which are separated by a space.
The command header contains one or more key fields. The command with question mark as postfix is a
query command. Commands are divided into common commands and instrument-specific commands
that are different in syntactic structure. SCPI has the following features:
1) The SCPI is established for the test functions rather than instrument operation description.
2) The SCPI reduces the repetition of the realization process of similar test functions, thus ensuring the
programming compatibility;
3) Remote control message is defined in a layer that is independent of the communication physical
layer hardware.
4) The SCPI is irrelated with the programming methods and languages, and the SCPI test program is
easy to be transplanted;
5) The SCPI is scalable so that it is applicable to measurement control on different scales.
6) Scalability makes SCPI
a ―Live‖ standard.
If you are interested in learning more about SCPI, please refer to:
IEEE Standard 488.1-1987, IEEE Standard Digital Interface for
Programmable Instrumentation. New York, NY, 1998.
IEEE Standard 488.2-1987, IEEE Standard Codes, Formats, Protocols and Comment
Commands for Use with ANSI/IEEE Std488.1-1987. New York, NY, 1998
Standard Commands for Programmable Instruments (SCPI) VERSION 1999.0.
For the collection of SCPIs, classification and description of 1465 series signal generator, please refer to:
1)
―3 SCPI‖ of this manual;
2) Appendix B Lookup Table of SCPI in this manual.