E1200 HT 260-3
8BMaintenance
23.04.07
00401010_41087
9-61
9.8.9
Adjusting Light Sensors and Limit Switches (Built up to 05/2003)
1. Adjust the "Wafer in transport carrier" sensor as follows:
—
Stick reflex foil to the port angle.
—
Place the transport carrier into the port seat. A wafer is located in slit 25. The
flat is pointing downwards.
—
Adjust the sensor so that the light beam is interrupted.
2. Adjust the "Transport carrier in port seat" sensor as follows:
—
Stick reflex foil to the port cover holding angle.
—
Adjust the sensor so that the light beam is interrupted when the transport
carrier stands correctly in the port seat, i. e. with closed side towards the
operator. The LED is switched off.
3. Adjust the "Wafer in process boat" sensor as follows:
The sensor operates with a higher degree of reliability if it is slightly inclined during
adjustment. This directs the sensor towards the wafer surface and not towards the
wafer circumference.
—
The sensor is mounted to the holding arm of the top level holders, the reflex
foil is below the opposite top level holder. Adjust the sensor so that the
sensor's light beam is reflected when there are no wafers in the process boat.
—
Use the serial commands to check the sensor monitoring range. The sensor
position results from this setting procedure, because the scanning or moving
distances are fixed in an EPROM.
—
Check if the sensor recognizes the wafers in the process boat when the slider
or wafer handler is moved at high speed.
4. Check the "Pick up elevator overload LIFT UP" sensor. To do this, manually lift the
pick up elevator, then press down against the pick up elevator during the lifting
process. The downward movement must be stopped.
5. Check the "Boat in the slider" sensor. The slider must reach the microswitch at
reference stop without process boat.
6. Adjust the "Wafer handler at lift side" limit switch. The emergency stop must be
activated.
7. Adjust the "Port free" sensor. The sensor must recognize the wafer handler when it
stands in the port's working area.
8. Check the "Lifting overload LIFT UP" sensor. To do this, manually lift the port, then
press down against the port during the lifting process. The downward movement
must be stopped.
9. Check the "Lifting overload LOWER" sensor. To do this, manually lower the port,
then press upwards against the port during the lifting process. The downward
movement must be stopped.
10. Check the "No boat on the slider" limit switch.
Содержание E1200 HT 260-3
Страница 1: ...Operating Instructions for Horizontal Furnace Equipment E1200 HT 260 3 Version 1 0 1_41087 11 ...
Страница 2: ...E1200 HT 260 3 23 04 07 00401010_41087 ...
Страница 4: ...E1200 HT 260 3 Document Information 23 04 07 00401010_41087 ...
Страница 16: ...E1200 HT 260 3 Index 23 04 07 00401010_41087 ...
Страница 18: ...E1200 HT 260 3 List of Figures 23 04 07 00401010_41087 ...
Страница 20: ...E1200 HT 260 3 List of Tables 23 04 07 00401010_41087 ...
Страница 26: ...E1200 HT 260 3 0BOperating Instruction Remarks 23 04 07 1 6 00401010_41087 ...
Страница 34: ...E1200 HT 260 3 1BIntroduction 23 04 07 2 8 00401010_41087 ...
Страница 50: ...E1200 HT 260 3 2BSafety 23 04 07 3 16 00401010_41087 ...
Страница 78: ...E1200 HT 260 3 4BTransport 23 04 07 5 4 00401010_41087 ...
Страница 180: ...E1200 HT 260 3 8BMaintenance 23 04 07 9 76 00401010_41087 ...
Страница 228: ...E1200 HT 260 3 10BSpare and Wearing Parts 23 04 07 11 2 00401010_41087 ...