7 - MAINTENANCE
As required
Fuel pre-filter - Drain fluid
Drain water and sediment from the fuel pre-filter as required. In certain geographic regions and climates, it may be
necessary to drain condensation more frequently.
Prior operation:
Keep all non-authorized personnel clear of the area. Park the machine on a firm, level surface in neutral with the
parking brake applied. Lower the bucket/attachment to the ground. Turn off the engine. Install the transport/service
link into the locked position.
Drain fuel pre-filter condensation
1. Open the engine hood. Locate the pre-filter in the en-
gine compartment on the right-hand side of the ma-
chine.
LEIL18WHL1173AA
1
2. Remove the water sensor connector from the bottom
of the pre-filter.
LEIL18WHL1173AA
2
3. Open the drain valve on the fuel pre-filter by turning
counterclockwise two or three turns.
4. Drain the water and/or contaminants from the pre-filter
into a suitable container until clean fuel flows.
NOTICE:
do not allow fuel to spill on engine or ground.
5. Close the drain valve. Reconnect the electrical con-
nection. Check for leaks.
LEIL18WHL1172AA
3
7-145
Содержание 721G Stage IV
Страница 24: ...1 GENERAL INFORMATION Waste Handler WH configuration LEIL18WHL1118FB 3 721G 1 18 ...
Страница 26: ...1 GENERAL INFORMATION LEIL17WHL2018FB 5 821G 1 20 ...
Страница 29: ...1 GENERAL INFORMATION LEIL19WHL0584H 1 1 23 ...
Страница 30: ...1 GENERAL INFORMATION 1 24 ...
Страница 51: ...2 SAFETY INFORMATION Empty tool LEEN11T0024AA 20 2 21 ...
Страница 84: ...2 SAFETY INFORMATION 2 54 ...
Страница 154: ...3 CONTROLS AND INSTRUMENTS Select the passcode to delete from the system and con firm LEIL16WHL1551AA 96 3 70 ...
Страница 162: ...3 CONTROLS AND INSTRUMENTS Inducement and validation re starts LEIL14WHL0394HA 2 3 78 ...
Страница 163: ...3 CONTROLS AND INSTRUMENTS Validation re start procedure LEIL15WHL0608HA 3 3 79 ...
Страница 189: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 7 4 15 ...
Страница 191: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 9 4 17 ...
Страница 193: ...4 OPERATING INSTRUCTIONS RCPH10WHL045BAH 12 4 19 ...
Страница 208: ...4 OPERATING INSTRUCTIONS 4 34 ...
Страница 222: ...5 TRANSPORT OPERATIONS 5 14 ...
Страница 259: ...7 MAINTENANCE LEIL17WHL1665H 5 721G 7 21 ...
Страница 260: ...7 MAINTENANCE LEIL17WHL1665H 6 821G 7 22 ...
Страница 265: ...7 MAINTENANCE DEF AdBlue level faults failures and engine power loss levels LEIL15WHL0607HA 2 7 27 ...
Страница 266: ...7 MAINTENANCE DEF AdBlue quality faults failures and engine power loss levels LEIL15WHL0609HA 3 7 28 ...
Страница 267: ...7 MAINTENANCE DEF AdBlue technical faults LEIL14WHL0392HA 4 7 29 ...
Страница 291: ...7 MAINTENANCE LEIL18WHL1152AA 14 821G 7 53 ...
Страница 300: ...7 MAINTENANCE LEIL15WHL1846AB 2 821G 7 62 ...
Страница 313: ...7 MAINTENANCE LEIL18WHL1154FA 1 LEIL18WHL1155FA 2 7 75 ...
Страница 360: ...7 MAINTENANCE 9 Re install all the covers guards and steps previously removed 7 122 ...
Страница 417: ...7 MAINTENANCE Waste Handler WH models LEIL17WHL2020FA 2 7 179 ...
Страница 436: ...8 SPECIFICATIONS 721G Loader Lift Arms Specifications LEIL16WHL0629FB 1 8 10 ...
Страница 445: ...8 SPECIFICATIONS LEIL16WHL0629FB 4 8 19 ...
Страница 461: ...8 SPECIFICATIONS LEIL16WHL0629FB 10 8 35 ...
Страница 470: ...8 SPECIFICATIONS LEIL16WHL0629FB 13 8 44 ...
Страница 480: ...8 SPECIFICATIONS 8 54 ...
Страница 516: ...9 ACCESSORIES 9 36 ...
Страница 520: ...Windows 3 86 Windshield washer fluid level Check 7 163 ...
Страница 521: ......