OPERATING CONDITIONS
Working zone
Specification
Value
Unit
Temperature range
Ambient temperature 5-45
°C
Relative air humidity,
maximum
60 (without condensing)
%
Conditions
Only operate the machine tool in the dust-free environment!
Avoid direct impact of dampness, dust and frost.
Do not operate in strong electric and magnetic fields!
Do not operate the machine tool in explosive atmosphere!
TECHNICAL DATA - T-7010
Dimensions of the machine
Noise emission
The data define the sound level of the noise exposure at the workplace of the operator and sound power level of the
machine tool.
The emission values meet standards EN ISO 3744, EN 12418 and Directive 2005/88/EC.
Specification
Value
Unit
Length
1730
mm
Width
820
mm
Height
1680
mm
Empty weight
125
kg
Operating weight
157
kg
Specification
Value
Unit
Rated voltage
230
400
V
Rated frequency
50
50
Hz
Capacity
2,8
4
kW
Power input
18
10
A
Starting current
30
25
A
Required fuse
20
16
A
Cutting shaft
rotation speed
1450
1450
U/min
Motor protection class
IP55
IP55
Motor duty type
S6
S6
Specification
Value
Unit
max. length
625
mm
max. width
590
mm
max. height
230
mm
max. weight
25
kg
Specification
Value
Unit
Water tank
30
l
Diamond blade
700
mm
Bore
25.40
mm
Flange Ø
130
mm
Vibration level
2,3
m/s2
Measuring tolerance
Vibration level
0,2
m/sec^2
Without load
Full load
Sound pressure level
76 dB (A)
89 dB (A)
Sound power level
78 dB (A)
91 dB (A)
Guaranteed sound
power level
89 dB (A)
Measuring tolerance
Value
Sound pressure level
4 dB (A)
Sound power level
2,5 dB (A)
Содержание T-3510
Страница 45: ...89 88 WIRING DIAGRAM T 4010 230V WIRING DIAGRAM T 3510 400V...
Страница 46: ...91 90 WIRING DIAGRAM T 5010 230V WIRING DIAGRAM T 4010 400V...
Страница 47: ...93 92 WIRING DIAGRAM T 6010 230V WIRING DIAGRAM T 5010 400V...
Страница 48: ...95 94 WIRING DIAGRAM T 7010 230V WIRING DIAGRAM T 6010 400V...
Страница 50: ...99 98...
Страница 51: ...www carat tools eu www carat tools com www carat tools be www carat tools nl www carat tools dk...