3-37
CHAPTER 3 DISASSEMBLY & REASSEMBLY
4) Place the reading holder
{
1
upward, re-
move the screw
{
2
(M3, self-tapping,
black) and remove the side plate
{
3
. In the
same way, remove the side plate on the
opposite side. Slide the reading holder,
and while unhooking the fitting parts
{
4
(7
pairs), remove it.
Note:
The right side plate differs from the left
side plate in shape. The right side plate
shown below has a stopper
{
5
.
Figure 3-517
5) Lift the CIS unit
{
1
, and while removing
both flat cables
{
2
from the slit, remove
the unit.
Figure 3-518
6) Remove 2 flat cables
{
1
from the con-
nectors. While unhooking the fitting parts,
remove 2 grounding plates
{
2
.
Note:
The connector has a lock. Release the
lock according to the previous section,
“2. Reading PCB”.
Figure 3-519
Notes on assembling
The grounding plates are same, but as-
semble them by aligning vertical and
horizontal directions with original positions.
Do not forget to mount a guide ring on the
shaft on the back side of the CIS unit.