CHAPTER 3 DISASSEMBLY & REASSEMBLY
5. Platen Motor
1) Remove the eject tray unit.
2) Remove the cable
{
1
connected to the
platen motor.
Figure 3-712
3) Remove the entrance upper unit.
4) Remove the reading roller (front) and
platen roller.
5) Remove 2 screws
{
1
(M3, round tip) and
remove the motor unit
{
2
.
Figure 3-713
6) Remove the pulley
{
1
and belt
{
2
. Re-
move 2 screws
{
3
(M3, round tip) and
remove the mounting plate
{
4
.
Figure 3-714
7) Remove 2 screws
{
1
(M3, round tip) and
remove the motor mount
{
3
from the
platen motor
{
2
.