3-48
COPYRIGHT © CANON ELECTRONICS INC. 2008
CANON DR-X10C FIRST EDITION
CHAPTER 3 DISASSEMBLY & REASSEMBLY
5) Remove the cable
{
1
and screw
{
2
(M3,
round tip) and remove the staple PCB
{
3
.
Figure 3-706
Notes on assembling
Fit the cable
{
1
into the groove
{
2
in the
cover. If the cable extrudes outside the
groove, it is caught.
Figure 3-707
3. Ultrasonic Sensor PCB
1) Remove the upper front cover and en-
trance upper unit.
2) Remove the main drive PCB.
Note:
To reserve work space for removing the
cable connected to the ultrasonic sen-
sor PCB, remove the PCB mounting
plate in the next step in addition to these
parts.
3) Remove 9 screws
{
1
(TP head) and re-
move the PCB mounting plate
{
2
.
Figure 3-708