CHAPTER 4 INSTALLATION & MAINTENANCE
I. INSTALLATION
1. Choosing Location
The following requirements should be
met when installing this machine. The ser-
vice technician should inspect the planned
location before delivery.
The power supply must be able to be
connected separately from a reference
voltage outlet
If a ground wire must be connected, con-
nect it to the correct location shown below.
1) Ground terminal of the outlet
2) Ground wire for which grounding work for
office equipment is performed
Do not install this machine on a weak
table or an inclined or unstable location.
The weight of the main body is approx.
39 kg.
The temperature should be between
10
°
C and 32.5
°
C and the relative humid-
ity should be between 20% and 80%.
However, since the performance is guar-
anteed at a temperature between 15
°
C
and 27.5
°
C and a relative humidity be-
tween 25% and 75%, this machine
should be installed in this range.
This machine should not be installed
near water faucets, boilers, humidifiers,
refrigerators, etc. and should not be put
in a location where the temperature or
humidity changes abruptly.
This machine should not be exposed to
open flames, dust, ammonia fumes, di-
rect sunlight, vibration, or electromag-
netic wave.
If it has to be placed in a sunny place, the
windows should be curtained to avoid di-
rect sunlight.
There should be an enough space
around this machine for operation,
maintenance and ventilation.
Since there are a ventilation hole and a
power cord on the rear side, do not push
this machine against the wall.
960 mm or more
730 mm or more
:100 mm or more
660 mm or more
Figure 4-101
Ensure to provide a carry-in route and a
means of transporting this machine in the
packing condition. The packing weight is
approx. 53 kg, and the dimensions are
approx. 730 (W)
×
700 (D)
×
600 (H) mm.