COPYRIGHT © CANON ELECTRONICS INC. 2008 CANON DR-X10C FIRST EDITION
3-33
CHAPTER 3 DISASSEMBLY & REASSEMBLY
6) Remove the cable from cable guides on
the bottom plate. Remove
2 screws
{
1
(M3, TP head) on the both sides and pull
out the reading unit (lower)
{
2
.
Note:
Do not pull it excessively because a
cable is connected to it.
Coil springs are mounted in the lower
part of the reading unit fixing part. Do
not lose it.
Figure 3-504
7) Remove 3 connectors
{
1
and remove the
reading unit (lower)
{
2
.
Figure 3-505
Notes on assembling
Do not nip the cable. Insert the cable into
the cable holder of the reading unit and the
cable guide of the bottom plate.
2. Reading PCB
1) Remove the reading unit (lower).
2) Remove 3 connectors
{
1
and remove the
cable from the cable guides of the 2 cable
covers
{
2
.
Figure 3-506
3) Unhook 2 pairs of the fitting parts
{
1
and
remove the cable cover
{
2
. In the same
way, remove the cable cover on the op-
posite side.
Figure 3-507