![Cadex C8000 Скачать руководство пользователя страница 278](http://html1.mh-extra.com/html/cadex/c8000/c8000_user-manual_3250378278.webp)
C8000 Battery Testing System User Manual
266
4
C-Code Parameters
The following table lists the parameters for c-codes. Note that not all parameters are used by all
chemistries.
Field
Description
Compatible
Chemistry
Limits
Units
Additional
requirements
Typical Range(s)
SM-BUS
Imported
Registers
Min.
Max.
Notes:
Chemistry
Battery
Chemistry
All
N/A
N/A
N/A
----
N/A
0x22
Any change to
this field to
affect all other
fields
Number of
Cells
Cells
All
1
NiMH = 30
N/A
----
N/A
No
Maximum
Value is
Chemistry
dependent
(Any change to
this field to
affect all other
fields)
NiCD = 30
SLA = 18
Li = 10
Primary = 30
LiPh = 10
Rating
Capacity rating
of the battery
stated in mAh
All
0.050
1000
Ah
----
None
0x18
Any change to
this field to
affect all other
fields
Minimal
Safe
Operating
The minimal
Voltage allowed
for the battery.
NiMH &
NiCD
0.320 *
cells
<MaxVoltage
V
----
----
No
----
Li, SLA
1.000 *
cells
----