Port commissioning overview
12
Changing CIMOM server credentials
You can edit the CIMOM server credentials for one or more CIMOM servers at the same time.
1. Select Configure > Port Commissioning > Setup.
The Port Commissioning Setup dialog box displays (
Figure 135
).
2. Select one or more CIMOM servers from the System List table and click Change Credentials.
The Edit Credentials dialog box displays. If you selected one CIMOM server, the credentials for
the selected server display in the dialog box. If you selected more than one CIMOM server, the
credential fields are empty.
3. (Optional) Enter a user identifier for the CIMOM server in the User ID field.
The user identifier cannot be over 128 characters.
4. (Optional) Enter a password in the Password field.
The password cannot be over 512 characters.
5. Click OK to close the Edit Credentials dialog box.
The Port Commissioning Setup dialog box and the status of the selected CIMOM server rows
displays “Credentials Updated”.
To validate the credentials, refer to
“Testing CIMOM server credentials”
on page 372.
6. Click OK to close the Port Commissioning Setup dialog box.
Testing CIMOM server credentials
You should validate the CIMOM server credentials before you decommission or recommission
ports. During the decommission or recommission of an F-Port, the Management application
validates the CIMOM server credentials.
1. Select a device and select Configure > Port Commissioning > Setup.
The Port Commissioning Setup dialog box displays (
Figure 135
).
2. Select one or more CIMOM servers from the System List table and click Test.
The status of the selected CIMOM server rows display “Testing” in the System List table. When
testing is complete, the CIMOM server connectivity status displays. Valid status options
include:
•
OK — CIMOM server contact successful with current credentials.
•
Not Contacted Yet — CIMOM servers configured, connectivity not tested yet.
•
Credentials Updated — Credentials changed, connectivity not tested yet.
•
Credentials Failed — CIMOM server contact failed with current credentials.
•
Not Reachable — CIMOM server not reachable.
•
Wrong Namespace— CIMOM server namespace is incorrect.
3. Click OK to close the Port Commissioning Setup dialog box.
When the test is complete, an application event displays in the Master Log detailing success or
failure.
Содержание Network Advisor 12.0.0
Страница 36: ...xxxvi Brocade Network Advisor SAN User Manual 53 1002696 01...
Страница 82: ...34 Brocade Network Advisor SAN User Manual 53 1002696 01 License downgrade 2...
Страница 86: ...38 Brocade Network Advisor SAN User Manual 53 1002696 01 Uninstalling a patch 3...
Страница 122: ...74 Brocade Network Advisor SAN User Manual 53 1002696 01 VM Manager discovery 4...
Страница 184: ...136 Brocade Network Advisor SAN User Manual 53 1002696 01 Fabric tracking 5...
Страница 214: ...166 Brocade Network Advisor SAN User Manual 53 1002696 01 User profiles 6...
Страница 236: ...188 Brocade Network Advisor SAN User Manual 53 1002696 01 Searching for an assigned event filter 7...
Страница 284: ...236 Brocade Network Advisor SAN User Manual 53 1002696 01 User defined performance monitors 8...
Страница 320: ...272 Brocade Network Advisor SAN User Manual 53 1002696 01 Grouping on the topology 9...
Страница 336: ...288 Brocade Network Advisor SAN User Manual 53 1002696 01 Microsoft System Center Operations Manager SCOM plug in 10...
Страница 434: ...386 Brocade Network Advisor SAN User Manual 53 1002696 01 Port Auto Disable 12...
Страница 442: ...394 Brocade Network Advisor SAN User Manual 53 1002696 01 Exporting Host port mapping 13...
Страница 450: ...402 Brocade Network Advisor SAN User Manual 53 1002696 01 Exporting storage port mapping 14...
Страница 536: ...488 Brocade Network Advisor SAN User Manual 53 1002696 01 Virtual FCoE port configuration 16...
Страница 552: ...504 Brocade Network Advisor SAN User Manual 53 1002696 01 Security configuration deployment 17...
Страница 878: ...830 Brocade Network Advisor SAN User Manual 53 1002696 01 Removing thresholds 24...
Страница 922: ...874 Brocade Network Advisor SAN User Manual 53 1002696 01 VLAN routing 26...
Страница 990: ...942 Brocade Network Advisor SAN User Manual 53 1002696 01 SAN Connection utilization 29...
Страница 998: ...950 Brocade Network Advisor SAN User Manual 53 1002696 01 Removing a frame monitor from a switch 30...
Страница 1138: ...1090 Brocade Network Advisor SAN User Manual 53 1002696 01 Call Home Event Tables B...
Страница 1144: ...1096 Brocade Network Advisor SAN User Manual 53 1002696 01 IP Performance monitoring events C...
Страница 1186: ...1138 Brocade Network Advisor SAN User Manual 53 1002696 01 Regular Expressions F...
Страница 1486: ...1438 Brocade Network Advisor SAN User Manual 53 1002696 01 Views H...