962
Brocade Network Advisor SAN User Manual
53-1002696-01
Adding a policy monitor
31
FIGURE 414
Add Policy Monitor dialog box, Switch/Router Checks tab
a. Select one or more of the following checks in the Available Checks list to include them in
the policy monitor:
For more information about these checks and fixes for rule violations, refer to
“Switch and
router policy monitors”
on page 953.
•
Select the Check if the product is configured to send events to this server check to
determine if the Management application server is registered as an SNMP recipient
and Syslog recipient.
•
Select the Check for redundant connections to neighboring switches (SAN only) check
to determine if there are at least the minimum number of configured ISLs between
each switch pair.
•
Select the Check for HTTPS (secure HTTP) configuration check to check each target to
see if HTTPS is active for device data transmission.
•
Select the Check if the product is configured to send Upload Failure Data Capture to
an FTP server (SAN only) check to determine the following configurations:
– Upload Failure Data Capture is enabled on the selected switches.
– A configured FTP Server is accessible.
– You have write permission to the directory.
•
Select the Check for SSH (secure Telnet) configuration check to check each target to
see if SSH is enabled for device data transmission.
•
Select the Check for SNMPv3 (secure SNMP) configuration check to check each target
to see if SNMPv3 is active for device data transmission and SNMPv1 and SNMPv2 are
not configured.
b. Click the right arrow button to move the selected checks to the Selected Checks list.
Содержание Network Advisor 12.0.0
Страница 36: ...xxxvi Brocade Network Advisor SAN User Manual 53 1002696 01...
Страница 82: ...34 Brocade Network Advisor SAN User Manual 53 1002696 01 License downgrade 2...
Страница 86: ...38 Brocade Network Advisor SAN User Manual 53 1002696 01 Uninstalling a patch 3...
Страница 122: ...74 Brocade Network Advisor SAN User Manual 53 1002696 01 VM Manager discovery 4...
Страница 184: ...136 Brocade Network Advisor SAN User Manual 53 1002696 01 Fabric tracking 5...
Страница 214: ...166 Brocade Network Advisor SAN User Manual 53 1002696 01 User profiles 6...
Страница 236: ...188 Brocade Network Advisor SAN User Manual 53 1002696 01 Searching for an assigned event filter 7...
Страница 284: ...236 Brocade Network Advisor SAN User Manual 53 1002696 01 User defined performance monitors 8...
Страница 320: ...272 Brocade Network Advisor SAN User Manual 53 1002696 01 Grouping on the topology 9...
Страница 336: ...288 Brocade Network Advisor SAN User Manual 53 1002696 01 Microsoft System Center Operations Manager SCOM plug in 10...
Страница 434: ...386 Brocade Network Advisor SAN User Manual 53 1002696 01 Port Auto Disable 12...
Страница 442: ...394 Brocade Network Advisor SAN User Manual 53 1002696 01 Exporting Host port mapping 13...
Страница 450: ...402 Brocade Network Advisor SAN User Manual 53 1002696 01 Exporting storage port mapping 14...
Страница 536: ...488 Brocade Network Advisor SAN User Manual 53 1002696 01 Virtual FCoE port configuration 16...
Страница 552: ...504 Brocade Network Advisor SAN User Manual 53 1002696 01 Security configuration deployment 17...
Страница 878: ...830 Brocade Network Advisor SAN User Manual 53 1002696 01 Removing thresholds 24...
Страница 922: ...874 Brocade Network Advisor SAN User Manual 53 1002696 01 VLAN routing 26...
Страница 990: ...942 Brocade Network Advisor SAN User Manual 53 1002696 01 SAN Connection utilization 29...
Страница 998: ...950 Brocade Network Advisor SAN User Manual 53 1002696 01 Removing a frame monitor from a switch 30...
Страница 1138: ...1090 Brocade Network Advisor SAN User Manual 53 1002696 01 Call Home Event Tables B...
Страница 1144: ...1096 Brocade Network Advisor SAN User Manual 53 1002696 01 IP Performance monitoring events C...
Страница 1186: ...1138 Brocade Network Advisor SAN User Manual 53 1002696 01 Regular Expressions F...
Страница 1486: ...1438 Brocade Network Advisor SAN User Manual 53 1002696 01 Views H...