background image

CAUTION
Before plugging a cable into any port, be sure to discharge the voltage stored on the cable by touching the electrical contacts to
ground surface.

DANGER

If the installation requires a different power cord than the one supplied with the device, make sure you use a power cord
displaying the mark of the safety agency that defines the regulations for power cords in your country. The mark is your
assurance that the power cord can be used safely with the device.

Preparing the installation site

EPS4000 external power supplies can be mounted in a standard 19-inch equipment rack or on a flat surface.

The installation site should meet these requirements:

Be at the center of all the devices you want to link, and near a power outlet.

Maintain temperatures within 0 to 50°C (32 to 122°F) and humidity levels within 5 to 95%, non-condensing.

Provide adequate space (approximately 5.08 cm [2 in.]) on all sides for proper airflow.

Be accessible for installing, cabling, and maintaining the devices.

Allow the status LEDs to be clearly visible.

Allow for twisted-pair cables to be routed away from power lines, fluorescent lighting fixtures, and other sources of electrical
interference, such as radios and transmitters.

Provide a separate grounded power outlet that provides 100 to 240 VAC, 50 - 60 Hz, is within 2.44 m (8 ft) of each device,
and is powered from an independent circuit breaker.

As with any electrical equipment, a filter or surge suppressor is recommended.

Rack-mount installation considerations

Before mounting the external power supply in a rack, consider the following factors:

Temperature: Because the temperature within a rack assembly may be higher than the ambient room temperature, check that
the rack-environment temperature is within the specified operating temperature range.

Airflow: Be sure that the airflow direction for all equipment in a rack is the same or consistent.

Mechanical loading: Do not place any equipment on top of a rack-mounted device.

Circuit overloading: Be sure that the supply circuit to the rack assembly is not overloaded.

Grounding: Rack-mounted equipment should be properly grounded.

Installing the device

You can install the device on a desktop or in an equipment rack.

DANGER

Mount the devices you install in a rack as low as possible. Place the heaviest device at the bottom and progressively place
lighter devices above.

Installing the EPS4000

Brocade ICX 7250 Switch Hardware Installation Guide

53-1003898-02

69

Содержание ICX 7250

Страница 1: ...HARDWARE INSTALLATION GUIDE Brocade ICX 7250 Switch Hardware Installation Guide 53 1003898 02 15 May 2016 ...

Страница 2: ...s features that may not be currently available Contact a Brocade sales office for information on feature and product availability Export of technical data contained in this document may require an export license from the United States government The authors and Brocade Communications Systems Inc assume no liability or responsibility to any person or entity with respect to the accuracy of this docu...

Страница 3: ...tallation precautions 24 General precautions 24 Lifting precautions 24 Power precautions 24 Preparing the installation site 25 Cabling infrastructure 25 Installation location 25 Rack mount installation considerations 25 Installing the device 26 Desktop installation 26 Installing the device into a rack 27 Wall mount installation 57 Connecting devices in a traditional stack 59 Stacking ports and tru...

Страница 4: ...s 78 Other 78 Weight and physical dimensions 78 Environmental requirements 78 Regulatory compliance EMC 79 Regulatory compliance safety 79 Regulatory compliance environmental 79 Configuring the Device 81 Configuration tasks 81 PC or terminal attachment 81 Password assignment 82 Assigning passwords 83 Recovering from a lost password 83 IP address configuration 84 Devices running Layer 2 software 84...

Страница 5: ...cade ICX 7250 Switch Technical Specifications 101 System specifications 101 Ethernet 101 LEDs 102 Other 102 Weight and physical dimensions 102 Environmental requirements 103 Power supply specifications per PSU 103 Power consumption idle configuration 104 Power consumption typical configuration 105 Power consumption maximum configuration 105 Data port specifications Ethernet 106 Serial port specifi...

Страница 6: ...ny statement 113 KCC statement Republic of Korea 113 VCCI statement 113 Cautions and Danger Notices 115 Cautions 115 General cautions 115 Electrical cautions 116 Danger Notices 117 General dangers 117 Electrical dangers 118 Dangers related to equipment weight 119 Laser dangers 119 ...

Страница 7: ...tax examples Command syntax conventions Bold and italic text identify command syntax components Delimiters and operators define groupings of parameters and their logical relationships Convention Description bold text Identifies command names keywords and command options italic text Identifies a variable value In Fibre Channel products a fixed value provided as input to a command option is printed ...

Страница 8: ...cumentation for your product and additional Brocade resources You can download additional publications supporting your product at www brocade com Select the Brocade Products tab to locate your product then click the Brocade product name or image to open the individual product page The user manuals are available in the resources module at the bottom of the page under the Documentation category To g...

Страница 9: ...ade Supplemental Support augments your existing OEM support contract providing direct access to Brocade expertise For more information contact Brocade or your OEM For questions regarding service levels and response times contact your OEM Solution Provider Document feedback To send feedback and report errors in the documentation you can use the feedback form posted with the document or you can e ma...

Страница 10: ...Preface Brocade ICX 7250 Switch Hardware Installation Guide 10 53 1003898 02 ...

Страница 11: ... are not included with the kit but are separately orderable For more information refer to Installing the 1U 1 5U and 2U Universal Kit for Four Post Racks XBR R000295 on page 29 and Installing the Universal Four Post Rack Kit XBR R000296 on page 43 Supported software This document is specific to the Brocade ICX 7250 running FastIron release 08 0 40 and later Brocade ICX 7250 Switch Hardware Install...

Страница 12: ...About This Document Brocade ICX 7250 Switch Hardware Installation Guide 12 53 1003898 02 ...

Страница 13: ...10 GbE uplink or stacking ports EPS4000 connection Brocade ICX 7250 24P 24 fixed 10 100 1000Base T PoE PoE ports 8 SFP 1 GbE or 10 GbE uplink or stacking ports EPS4000 connection Brocade ICX 7250 48 48 fixed 10 100 1000Base T non PoE ports 8 SFP 1 GbE or 10 GbE uplink or stacking ports EPS4000 connection Brocade ICX 7250 48P 48 fixed 10 100 1000Base T PoE PoE ports 8 SFP 1 GbE or 10 GbE uplink or ...

Страница 14: ...on a 48 port model 1 Out of band management port RJ 45 2 Console port mini USB 3 Slot 1 10 100 1000 Mbps ports RJ 45 4 Slot 2 SFP uplink or stacking ports 5 Reset button not a management interface shown for reference only The reset button allows you to restart the system without switching the power supply off and on or using the CLI When the reset button is pressed the system resets and the softwa...

Страница 15: ... ports 1 8 Brocade ICX 7250 48P RJ 45 PoE PoE ports 1 48 SFP ports 1 8 10 100 1000 BASE T ports All devices provide 24 or 48 RJ 45 ports that operate at 10 Mbps or 100 Mbps half or full duplex or at 1000 Mbps full duplex Because all ports support automatic MDI or MDI X operation you can use straight through cables for all network connections to PCs servers or other devices or hubs In addition it i...

Страница 16: ...the SFP ports the range is from 1 through 8 The following example shows how to specify port 2 in slot 1 of a device that is not part of a stack device config interface ethernet 1 1 2 Specifying a stacking port The port address format is stack unit slot port stack unit Specifies the stack unit ID For models that support stacking the range is from 1 through the maximum number of devices units that c...

Страница 17: ...onding ports 3 PoE PoE LEDs for corresponding ports NOTE The PoE PoE LEDs are reserved on models that do not support PoE or PoE operation FIGURE 7 Port status LEDs for SFP or SFP ports 1 SFP or SFP ports Overview Brocade ICX 7250 Switch Hardware Installation Guide 53 1003898 02 17 ...

Страница 18: ...7250 devices On Flashing Green The SFP port is operating at 10 Gbps Flashing indicates the port is transmitting and receiving user packets at 10 Gbps On Flashing Yellow The SFP port is operating at 1 Gbps Flashing indicates the port is transmitting and receiving user packets at 1 Gbps Off A link is not established with a remote port Out of band management port RJ 45 Green The management port link ...

Страница 19: ...c test in progress System reloads automatically Steady Yellow System self diagnostic test has detected a fault Fan thermal or any interface fault The user must reload the system MS Green The device is the Active controller Flashing indicates the system is initializing Yellow Indicates the device is the Standby controller Flashing indicates the system is in Master arbitration or selection state Off...

Страница 20: ...power supply EPS4000 that can provide DC power to the device in the event the internal power supply fails or for supplemental power for PoE or PoE applications The following figure shows an example of a typical rear panel for an ICX 7250 device FIGURE 10 ICX 7250 power supply connectors 1 External power supply EPS4000 connector 2 AC power supply socket NOTE The power connector for the EPS4000 is t...

Страница 21: ...supply by providing system power backup If the overall PoE requirement is less than the power budget of 370 W or 740 W the device can support 24 or 48 PoE ports The system power 12 volt supply portion of the EPS4000 can be used for internal system power redundancy TABLE 6 AC power supply and PoE and PoE usage Model Maximum power draw from AC line input Watts Number of PoE ports supported with inte...

Страница 22: ...Overview Brocade ICX 7250 Switch Hardware Installation Guide 22 53 1003898 02 ...

Страница 23: ...the contents of your shipping container If any items are missing contact the place of purchase ICX 7250 device Rack mounting kit containing two L shaped mounting brackets and two sets of eight sink head screws Wall mounting kit containing two wall mount screws and two plastic anchors Two post rack kit containing four rack mounting screws and four cage nuts One AC power cord US only Power cord reta...

Страница 24: ...s manual Powering on the system on page 62 Installation precautions Follow all precautions when installing a device General precautions DANGER All fiber optic interfaces use Class 1 lasers CAUTION Do not install the device in an environment where the operating ambient temperature might exceed 50 C 122 F CAUTION Make sure the airflow around the front sides and back of the device is not restricted L...

Страница 25: ...g requirements Maintain the operating environment as specified in the Technical Specifications Allow a minimum of 7 62 cm 3 in of space between the front and the back of the device and walls or other obstructions for proper airflow Allow at least 7 62 cm 3 in of space at the front and back of the device for the twisted pair fiber optic and power cabling The site should be accessible for installing...

Страница 26: ...desktop the wall or in an equipment rack DANGER Mount the devices you install in a rack as low as possible Place the heaviest device at the bottom and progressively place lighter devices above Desktop installation Complete the following steps to install the ICX 7250 device on a desktop or other flat surface The device you are installing might look different than the one in the following illustrati...

Страница 27: ...into a rack This section describes the procedures you use to mount the device into a rack The Brocade ICX 7250 can be installed in a 2 post or 4 post rack The device ships with a 2 post rack To use the rack that ships with the product refer to Installing the device using the included two post rack mount kit on page 28 To install the product into a four post rack you can order one of two four post ...

Страница 28: ...haped mounting brackets and two sets of eight sink head screws 2 Using a Phillips screwdriver attach the mounting brackets to the sides of the device using eight 6 32 sink head screws four screws on each side NOTE The 6 32 sink head screws are for front mounting Use the 8 32 screws for rear mounting FIGURE 12 Attaching the rack mounting brackets for the ICX 7250 3 Remove the two post rack kit from...

Страница 29: ...connected to the device and less interference in the aisle at the front of the rack NOTE Hardware devices illustrated in these procedures are only for reference and may not depict the device you are installing into the rack Installation requirements Review the installation and facility requirements for your product before mounting the device Refer to the hardware installation guide for your produc...

Страница 30: ...hillips torque screwdriver 1 4 inch slotted blade torque screwdriver CAUTION Use the screws specified in the procedure Using longer screws can damage the device Parts list The following parts are provided with the 1U 1 5U and 2U Universal Kit for Four Post Racks Installation XBR R000296 Installation Brocade ICX 7250 Switch Hardware Installation Guide 30 53 1003898 02 ...

Страница 31: ...ed off and disconnected from the fabric during this procedure NOTE The illustrations in the rack installation procedures show a 1U device but the instructions are the same for a 1 5U or 2U device The illustrations in the rack installation procedures are for reference only and may not show the actual device Complete the following tasks to install the device in a four post rack 1 Attaching the front...

Страница 32: ...nsert four 8 32 x 5 16 in flathead screws through the vertically aligned holes in the bracket and then into the holes on the side of the device Use the upper and lower screw holes leaving the center holes empty 3 Repeat Step 1 and Step 2 to attach the left front bracket to the left side of the device 4 Tighten all the 8 32 x 5 16 in screws to a torque of 15 in lb 17 cm kg FIGURE 15 Attaching the f...

Страница 33: ...and then into the holes on the side of the device Use the upper and lower screw holes leaving the center holes empty 4 Repeat Step 1 and Step 2 to attach the left extension bracket to the left side of the device 5 Tighten all the 8 32 x 5 16 in screws to a torque of 15 in lb 17 cm kg FIGURE 16 Attaching the extension brackets to the device 1 Bracket extensions 2 Screws 8 32 x 5 16 in flathead Phil...

Страница 34: ...e extensions Complete the following steps to attach the rear brackets to the extensions There are short and long rear brackets that you can use for this step Choose the correct bracket for the depth of your rack 1 Select the proper length rear bracket for your rack depth 2 Slide the right rear bracket onto the right extension as shown in Figure 18 The short rear brackets are shown Use the first an...

Страница 35: ...all the 6 32 x 1 4 in screws to a torque of 9 in lb 10 cm kg FIGURE 18 Attaching the rear brackets to the extensions 1 Rear brackets 2 Screws 6 32 x 1 4 in panhead Phillips Installation Brocade ICX 7250 Switch Hardware Installation Guide 53 1003898 02 35 ...

Страница 36: ...r bracket to the right rear rack post using two 10 32 x 5 8 in panhead screws and two retainer nuts as shown in Figure 20 Use the upper and lower holes in the bracket 2 Attach the left rear bracket to the left rear rack post using two 10 32 x 5 8 in panhead screws and two retainer nuts Use the upper and lower holes in the bracket 3 Tighten all the 10 32 x 5 8 in screws to a torque of 25 in lb 29 c...

Страница 37: ...evice but the instructions are the same for a 1 5U or 2U device The illustrations in the rack installation procedures are for reference only and may not show the actual device Complete the following tasks to install the device in a four post rack 1 Attaching the front brackets to the rear of the device on page 51 2 Attaching the extensions to the front of the device on page 52 3 Installing the dev...

Страница 38: ...hown in Figure 21 2 Insert four 8 32 x 5 16 in flathead screws through the vertically aligned holes in the bracket and then into the holes on the side of the device Use the upper and lower screw holes leaving the center holes empty 3 Repeat Step 1 and Step 2 to attach the left rear bracket to the left side of the device 4 Tighten all the 8 32 x 5 16 in screws to a torque of 15 in lb 17 cm kg FIGUR...

Страница 39: ... front extension to the left side of the device 5 Tighten all the 8 32 x 5 16 in screws to a torque of 15 in lb 17 cm kg FIGURE 22 Attaching the bracket extensions to the device 1 Extension brackets 2 Screws 8 32 x 5 16 in flathead Phillips Installing the device in the rack Complete the following steps to install the device in the rack 1 Position the device in the rack as shown in Figure 23 provid...

Страница 40: ...ts that you can use for this step Choose the correct bracket for the depth of your rack 1 Select the proper length rear bracket for your rack depth 2 Slide the right rear bracket onto the right extension as shown in Figure 24 The short rear brackets are shown Use the first and third vertical pairs of holes for the screws Refer to Figure 25 for the positioning of the medium or long brackets and scr...

Страница 41: ...taching the rear brackets to the extensions at the front of the device 1 Rear brackets short 2 Screws 6 32 x 1 4 in panhead Phillips Installation Brocade ICX 7250 Switch Hardware Installation Guide 53 1003898 02 41 ...

Страница 42: ...the right rear bracket to the right front rack post using two 10 32 x 5 8 in screws and two retainer nuts as shown in Figure 26 Use the upper and lower holes in the bracket 2 Attach the left rear bracket to the left front rack post using two 10 32 x 5 8 in screws and two retainer nuts Use the upper and lower holes in the bracket 3 Tighten all the 10 32 x 5 8 in screws to a torque of 25 in lb 29 cm...

Страница 43: ...he port side flush with the front posts With the nonport side flush with the rear posts in a recessed position A recessed position allows a more gradual bend in the fiber optic cables connected to the switch and less interference in the aisle at the front of the rack NOTE Although this document describes how to install both single height 1U and double height 2U switches the illustrations show a 1U...

Страница 44: ...fit into a rack with a maximum depth of 81 28 cm 32 in using the universal four post rack kit The maximum rack depth for a chassis less than 40 64 cm 16 in is 81 28 cm 32 in minus the difference between the chassis depth and 40 64 cm 16 in For example a chassis with a depth L of 35 56 cm 14 in is 5 08 cm 2 in smaller than 40 64 cm 16 in so it will install into a rack with a maximum depth of 81 28 ...

Страница 45: ...s 16 8 Screw 6 32 x 1 4 in panhead Phillips 8 9 Screw 10 32 x 5 8 in panhead Phillips 8 10 Retainer nut 10 32 8 Ensure that the items listed and illustrated in Figure 27 are included in the kit Note that not all parts may be used with certain installations depending on the device type CAUTION Use the screws specified in the procedure Using longer screws can damage the device Installation Brocade I...

Страница 46: ...rackets to the extensions on page 49 5 Attaching the rear brackets to the rack posts on page 50 Attaching the front brackets Complete the following steps to attach the front brackets to the device 1 Position the right front bracket with the flat side against the right side of the device at the front of the device as shown in Figure 28 2 Insert four 8 32 x 5 16 in flathead screws through the vertic...

Страница 47: ...ngth extension bracket for your rack depth 2 Position the right extension bracket along the side of the device as shown in Figure 29 3 Insert four 8 32 x 5 16 in flathead screws through the vertically aligned holes in the extension bracket and then into the holes on the side of the device Use the upper and lower screw holes leaving the center holes empty 4 Repeat step 1 and step 2 to attach the le...

Страница 48: ...the rail kit is secured to the rack 2 Attach the right front bracket to the right front rack post using two 10 32 x 5 8 in panhead screws and two retainer nuts Use the upper and lower holes in the bracket 3 Attach the left front bracket to the left front rack post using two 10 32 x 5 8 in panhead screws and two retainer nuts Use the upper and lower holes in the bracket 4 Tighten all the 10 32 x 5 ...

Страница 49: ... proper length rear bracket for your rack depth 2 Slide the right rear bracket onto the right extension and attach to the extension by inserting four 6 32 x 1 4 in panhead screws through the bracket holes If possible leave at least one empty vertical pair of holes between the screws for better support 3 Repeat step 2 to attach the left rear bracket to the left extension 4 Adjust the brackets to th...

Страница 50: ...e right rear rack post using two 10 32 x 5 8 in panhead screws and two retainer nuts as shown in Figure 32 Use the upper and lower holes in the bracket 2 Attach the left rear bracket to the left rear rack post using two 10 32 x 5 8 in panhead screws and two retainer nuts Use the upper and lower holes in the bracket 3 Tighten all the 10 32 x 5 8 in screws to a torque of 25 in lb 29 cm kg Installati...

Страница 51: ...eference only and may not show the actual device Complete the following tasks to install the device in a four post rack 1 Attaching the front brackets to the rear of the device on page 51 2 Attaching the extensions to the front of the device on page 52 3 Installing the device in the rack on page 53 4 Attaching the rear brackets to the extensions at the front of the device on page 54 5 Attaching th...

Страница 52: ...ear of the device 1 The Brocade device 2 Screws 8 32 x 5 16 in flathead Phillips 3 Front brackets Attaching the extensions to the front of the device Complete the following steps to attach the extension brackets to the front of the device There are medium and long extension brackets that you can use for this step Choose the correct extension for the depth of your rack 1 Select the proper length ex...

Страница 53: ... the rail kit is secured to the rack 2 Attach the right front bracket to the right rear rack post using two 10 32 x 5 8 in panhead screws and two retainer nuts Use the upper and lower holes in the bracket 3 Attach the left front bracket to the left rear rack post using two 10 32 x 5 8 in panhead screws and two retainer nuts Use the upper and lower holes in the bracket 4 Tighten all the 10 32 x 5 8...

Страница 54: ... bracket for your rack depth 2 Slide the right rear bracket onto the right extension as shown in Figure 36 The short rear brackets are shown Use the first and third vertical pairs of holes for the screws Refer to Figure 37 for the positioning of the short or long brackets and screws 3 Attach the brackets using four 6 32 x 1 4 in screws 4 Repeat step 2 and step 3 to attach the left rear bracket to ...

Страница 55: ...taching the rear brackets to the extensions at the front of the device 1 Rear brackets short 2 Screws 6 32 x 1 4 in panhead Phillips Installation Brocade ICX 7250 Switch Hardware Installation Guide 53 1003898 02 55 ...

Страница 56: ...he right rear bracket to the right front rack post using two 10 32 x 5 8 in screws and two retainer nuts as shown in Figure 38 Use the upper and lower holes in the bracket 2 Attach the left rear bracket to the left front rack post using two 10 32 x 5 8 in screws and two retainer nuts Use the upper and lower holes in the bracket 3 Tighten all the 10 32 x 5 8 in screws to a torque of 25 in lb 29 cm ...

Страница 57: ...ount the device with the port side down Complete the following steps to mount the device to a wall DANGER This equipment is suitable for mounting on concrete or other noncombustible surfaces only 1 Attach the four adhesive feet to the bottom of the device 2 Using a Phillips screwdriver attach the wall mount brackets to the sides of the device using four 6 32 sink head screws on each side Installat...

Страница 58: ...n the wall where you want to mount the device 4 Hammer two wall mount anchors into the holes on the wall 5 Use the two wall mount screws to fasten the device to the wall mount anchors Installation Brocade ICX 7250 Switch Hardware Installation Guide 58 53 1003898 02 ...

Страница 59: ...ks that are connected so that the stack is managed as a single entity A traditional stack contains devices from only one model in a product family Stacking ports and trunks There are eight SFP ports on the front panels of the ICX 7250 devices that support stacking which can be used as uplink data ports or as stacking ports The following figure shows the ports in slot 2 the top row consists of port...

Страница 60: ...gy there is a connection between each switch that carries two way communications across the stack The physical connection between the devices can use one port stacked port or two ports stacked trunk per trunk The stack uses a pair of ports n n 1 where n is odd and ranges from 1 through 7 even if there is only one physical connection between the devices in a stack The physical connections must be f...

Страница 61: ...d port and port 2 2 4 is connected to 3 2 8 even numbered port to even numbered port This is a stacked trunk configuration FIGURE 42 Linear stacking topology 1 First device in stack 2 Second device in stack 3 Third device in stack In a ring stacking topology there is an extra connection between the logical first and last devices forming a ring or closed loop The closed loop connection provides a r...

Страница 62: ...the equipment and should be easily accessible 1 Remove the power cord from the shipping container 2 Install the power cord clip 3 Attach the AC power cord to the AC connector on the rear panel 4 Insert the power cord plug into a 100V 240V outlet NOTE To turn the system off simply unplug the power cord or cords Installation Brocade ICX 7250 Switch Hardware Installation Guide 62 53 1003898 02 ...

Страница 63: ...by the EPS4000 Each RPS17 PSU can provide backup power to one ICX 7250 device Even though a fully populated EPS4000 can monitor up to sixteen connected devices the EPS4000 can provide backup power without performance degradation to only four ICX 7250 devices NOTE The primary source of 12 V power for an ICX 7250 device is the internal power supply The EPS4000 is designed to serve primarily as a bac...

Страница 64: ...redundancy at 12 V with each PSU Each RPS17 can deliver a maximum of 740 W at 54 V and 120 W at 12 V A fully populated EPS4000 has 8 DC power ports that can monitor up to 16 switches simultaneously and provide 12 V redundant power to four switches Provides power redundancy at 54 V and true extended PoE power support 1 1 and 1 2 cables support 54 V or 12 V distribution up to 1 meter Universal 100 2...

Страница 65: ... slot cover screws 8 Reset button sets EPS4000 configuration to factory default 9 System status indicators 10 Out of band Ethernet management port RJ 45 FIGURE 45 EPS4000 rear panel 1 DC power cable connector 1 2 DC power cable connector 2 3 DC power cable connector 3 4 DC power cable connector 4 5 DC power cable connector 5 Installing the EPS4000 Brocade ICX 7250 Switch Hardware Installation Guid...

Страница 66: ... LED State Description E1 1 E8 1 54 V1 E1 2 E8 2 54 V2 Off No connection Green EPS4000 is delivering up to 370 W PoE power to switch Amber Switch is connected to this channel but EPS4000 does not have sufficient PoE power for this channel Blinking amber This channel has a fault for example over current Blinking amber and green This channel has been granted PoE power but there is a fault on the cha...

Страница 67: ...urchase EPS4000 external power supply Rack mounting kit containing two L shaped mounting brackets and eight sink head screws Two post rack kit containing four rack mounting screws and four cage nuts Four rubber feet Console cable RJ 45 to DB9 adapter China ROHS sheet Read Me First document Configuration requirements The configuration requirements for the EPS4000 are the same as the for the ICX 725...

Страница 68: ...utions DANGER Make sure the rack housing the device is adequately secured to prevent it from becoming unstable or falling over DANGER Mount the devices you install in a rack as low as possible Place the heaviest device at the bottom and progressively place lighter devices above Power precautions CAUTION Use a separate branch circuit for each power cord which provides redundancy in case one of the ...

Страница 69: ...fixtures and other sources of electrical interference such as radios and transmitters Provide a separate grounded power outlet that provides 100 to 240 VAC 50 60 Hz is within 2 44 m 8 ft of each device and is powered from an independent circuit breaker As with any electrical equipment a filter or surge suppressor is recommended Rack mount installation considerations Before mounting the external po...

Страница 70: ...four adhesive feet to the bottom of the device NOTE The process is the same for multiple devices FIGURE 47 Attaching the adhesive feet to the device 2 Set the device on a flat surface near an AC power source making sure there is the specified amount of space on all sides of the device for proper airflow Mounting an external power supply in a rack two post DANGER Make sure the rack housing the devi...

Страница 71: ...ur cage nuts 2 Using a Phillips screwdriver attach the mounting brackets to the sides of the external power supply using 3 sink head screws on each side FIGURE 48 Attaching the mounting brackets to the device 3 Mount the external power supply in a rack using four rack mounting screws 4 Use the four cage nuts to screw the device to the rack mount holes Installing the EPS4000 Brocade ICX 7250 Switch...

Страница 72: ...RPS17 PSU You can install a new RPS17 Power Supply Unit PSU into EPS4000 while the device is powered on and running NOTE While installing a PSU wear an ESD wrist strap DANGER For safety reasons the ESD wrist strap should contain a series 1 megaohm resistor Perform the following steps to install an RPS17 PSU Installing the EPS4000 Brocade ICX 7250 Switch Hardware Installation Guide 72 53 1003898 02...

Страница 73: ...sert the PSU into the slot until it clicks into place Uninstalling an RPS17 PSU You can uninstall an RPS17 PSU from the EPS4000while the device is powered on and running NOTE While uninstalling a PSU wear an ESD wrist strap DANGER For safety reasons the ESD wrist strap should contain a series 1 megaohm resistor Perform the following steps to uninstall an RPS17 PSU 1 Put on the ESD wrist strap and ...

Страница 74: ...ort on the EPS4000 power supply Both cords deliver up to 120 W at 12 V You must use a 1 2 cord if you want an ICX 7250 48P device to share 54 V power with another device Both 1 1 and 1 2 cords will deliver only 370 W of 54 V power to an ICX 7250 24P device NOTE The headers on the cords are color coded to help you connect them correctly to the switch and the EPS4000 You must connect the cables tigh...

Страница 75: ...Port 1 cord Black 6 Switch side connector housing 1 2 cord 7 Latch screws Complete the following steps to connect the EPS4000 cord CAUTION Do not use the cable to connect two EPS4000 ports NOTE You can connect either end of the cable first Hot insertion is supported for cable installation Installing the EPS4000 Brocade ICX 7250 Switch Hardware Installation Guide 53 1003898 02 75 ...

Страница 76: ...the EPS4000 side connector of the EPS4000 DC cord to an available DC power port on the back of the EPS4000 4 Use a flat blade screwdriver to attach the latch screw on the DC cord to the EPS4000 When the screw is tightened securely all power supplies to your device will be active Powering on the system After you complete the physical installation you can power on the system NOTE The power outlet sh...

Страница 77: ...es Verifying proper operation After you have installed an external power supply verify that the device is working properly by plugging it into a power source and verifying that it passes the self test 1 Connect the power cord supplied with the device to the power connector on the power supply on the rear of the device 2 Insert the other end into a properly grounded electrical outlet 3 Verify that ...

Страница 78: ...e RJ 45 console cable DB9 adapter DB9 adapter for serial connection Weight and physical dimensions Fully loaded Populated with 4 RPS17 Power Supply Units PSUs Model Height Width Depth Weight empty Weight fully loaded EPS4000 4 37 cm 1 72 inches 43 7 cm 17 2 inches 40 6 cm 16 0 inches 4 87 kg 10 7 lb 8 35 kg 18 4 lb Environmental requirements Condition Operational Non operational Ambient temperatur...

Страница 79: ...iance environmental 2011 65 EU Restriction of the use of certain hazardous substance in electrical and electronic equipment EU RoHS 2012 19 EU Waste electrical and electronic equipment EU WEEE 94 62 EC packaging and packaging waste EU 2006 66 EC batteries and accumulators and waste batteries and accumulators EU battery directive 1907 2006 of the European Parliament and of the Council of 18 Decembe...

Страница 80: ...Installing the EPS4000 Brocade ICX 7250 Switch Hardware Installation Guide 80 53 1003898 02 ...

Страница 81: ...g the CLI with a direct serial connection IP address configuration on page 84 4 Once you power on the device and assign IP addresses the system is ready to accept network equipment Configuring IP parameters for devices running Layer 3 software on page 85 5 Test IP connectivity to other devices by pinging them and tracing routes Testing connectivity on page 89 6 Continue configuring the device usin...

Страница 82: ...Password assignment By default the CLI is not protected by passwords To secure CLI access Brocade strongly recommends assigning passwords Refer to the FastIron Ethernet Switch Administration Guide NOTE You can assign passwords using Brocade Network Advisor if an enable password for a Super User has been configured on the device The CLI contains the following access levels User EXEC The level you e...

Страница 83: ...sswords 4 Enter the following commands to set the port configuration and read only passwords device config enable port config password john device config enable read only password sam NOTE If you forget your Super User password refer to Recovering from a lost password on page 83 Passwords can be up to 32 characters long Recovering from a lost password By default the CLI does not require passwords ...

Страница 84: ...ctory test configuration if still present device erase startup config CAUTION Use the erase startup config command only for new systems If you enter this command on a system you have already configured the command erases the configuration If you accidentally do erase the configuration on a configured system enter the write memory command to save the running configuration to the startup config file...

Страница 85: ...ou know the subnet mask length In the previous example you could enter ip address 10 22 3 44 24 Use the secondary option of the ip address command parameter if you have already configured an IP address within the same subnet on the interface Configuring IP parameters for devices running Layer 3 software You must configure IP parameters for devices running Layer 3 software Configuring IP addresses ...

Страница 86: ...Layer 3 Virtual LAN VLAN configured on a Layer 3 device You can configure routing parameters on the virtual interface to enable the Layer 3 device to route protocol traffic from one Layer 3 VLAN to the other without using an external router NOTE The device uses the lowest MAC address on the device the MAC address of port 1 or 1 1 1 as the MAC address for all ports within all virtual interfaces you...

Страница 87: ...bs a 10 100Base TX or 1000Base T switch or another Brocade device a crossover cable is required as shown in the following figure If the hub is equipped with an uplink port it requires a straight through cable instead of a crossover cable NOTE The 802 3ab standard automatic MDI or MDIX detection calls for automatic negotiation of the connection between two 1000Base T ports In this case a straight t...

Страница 88: ...n MDI port or designate the port as an MDIX port For more information about this feature and how to configure it refer to the FastIron Ethernet Switch Administration Guide Connecting a network device to a fiber port For direct attachment from the device to a Gigabit NIC switch or router using a fiber optic transceiver you need fiber cabling with an LC connector To connect the device to another net...

Страница 89: ... 24G devices You can configure your device to monitor optical transceivers in the system either globally or by specified port When this feature is enabled the system monitors the temperature and signal power levels for the optical transceivers in the specified ports Console messages and syslog messages are sent when optical operating conditions fall below or rise above the SFP and SFP manufacturer...

Страница 90: ...the other actions do not resolve the problem try using a different port or a different cable SFP X1 X4 for ICX 7250 24G devices SFP X1 X8 for all other ICX 7250 devices On or flashing Green or Yellow Flashing yellow indicates the port is transmitting and receiving user packets at 1 Gbps The SFP port is operating at 10 Gbps Flashing green indicates the port is transmitting and receiving user packet...

Страница 91: ...hese actions contact Brocade Technical Support Tracing a route To determine the path through which a Brocade device can reach another device enter a command similar to the following at any level of the CLI on the device device traceroute 10 33 4 7 The CLI displays trace route information for each hop as soon as the information is received Traceroute requests display all responses to a given TTL In...

Страница 92: ...Configuring the Device Brocade ICX 7250 Switch Hardware Installation Guide 92 53 1003898 02 ...

Страница 93: ...able During system bootup the fans run at high speed If the switch does not detect any fans the switch shuts down After bootup the fans operate at low speed when the temperature of the switch is below the high limit temperature that is specified in the following table If the switch reaches the high limit temperature the fans operate at high speed until the switch reaches the low limit temperature ...

Страница 94: ...o of the module fans are detected as operating in opposite directions No action is performed The system follows the fan speed and shutdown policy as described in Temperature threshold levels on page 93 A syslog message is generated that describes the issue After system bootup the power supply and module fans are detected as operating in opposite directions No action is performed The system follows...

Страница 95: ... warning level 55 0 C degrees shutdown level 65 0 C degrees 1d02h07m29s W System Temperature is over warning level on unit 1 Dec 1 10 16 34 A System Stack unit 2 Temperature 46 0 C degrees warning level 70 0 C degrees shutdown level 80 0 C degrees Dec 1 10 16 34 A System Temperature on Unit 2 is over shutdown level system is going to be reset in 2 seconds Dynamic Log Buffer 50 lines 0d00h00m53s I ...

Страница 96: ...pu 20 percent busy from 318 sec ago 1 sec avg 2 percent busy 5 sec avg 1 percent busy 60 sec avg 1 percent busy 300 sec avg 1 percent busy Removing MAC address entries You can remove the following types of learned MAC address entries from the system MAC address table All MAC address entries All MAC address entries for a specified Ethernet port All MAC address entries for a specified VLAN A specifi...

Страница 97: ...r fiber optic module You can remove a copper or fiber SFP or SFP transceiver from a slot while the ICX 7250 device is powered on and running While removing a copper or fiber optic module be sure to wear an ESD wrist strap with a plug that can be inserted in the ESD connector on the ICX 7250 device DANGER For safety reasons the ESD wrist strap should contain a series 1 megaohm resistor To remove a ...

Страница 98: ...nsceiver on page 98 Installing a fiber optic transceiver You can install a new fiber optic transceiver in an SFP or SFP slot while the device is powered on and running While installing a transceiver wear an ESD wrist strap with a plug that can be inserted in the ESD connector on the ICX 7250 device DANGER For safety reasons the ESD wrist strap should contain a series 1 megaohm resistor DANGER All ...

Страница 99: ... optic transceiver 1 Remove the protective covering from the fiber optic port connectors and store the covering for future use NOTE Before cabling a fiber optic transceiver Brocade strongly recommends cleaning the cable connectors and the port connectors 2 Gently insert the cable connector a tab on each connector should face upward into the transceiver connector until the tabs lock into place 3 Ob...

Страница 100: ...ber optic transceiver Perform the following steps to cable a fiber optic transceiver 1 Remove the protective covering from the fiber optic port connectors and store the covering for future use NOTE Before cabling a fiber optic transceiver Brocade strongly recommends cleaning the cable connectors and the port connectors 2 Gently insert the cable connector a tab on each connector should face upward ...

Страница 101: ...CX 7250 24 One fan per device ICX 7250 24P Two fans per device ICX 7250 48 Two fans per device ICX 7250 48P Three fans per device Cooling Forced air circulation ICX 7250 24G front to back airflow All other models sides to back airflow System architecture Edge Ethernet switches ICX 7250 24G SFP uplink ports ICX 7250 24 ICX 7250 24P ICX 7250 48 ICX 7250 48P SFP uplink and stacking ports ICX 7250 24P...

Страница 102: ... port status DOWNLINK Software controlled LED green to indicate stacking uplink port status Stack ID Ten LEDs green to display stacking ID from 1 to 19 The LED marked 10 is used in conjunction with the others 1 through 9 to indicate stacking IDs 11 to 19 NOTE For those devices that support stacking the maximum stack size is 12 units Other System component Description RESET Reset button for hardwar...

Страница 103: ...ons N A Operating noise ICX 7250 24G 40 dBA ICX 7250 24 41 9 dBA ICX 7250 24P 44 7 dBA ICX 7250 48 44 5 dBA ICX 7250 48P 45 9 dBA N A Power supply specifications per PSU The EPS4000 and its power supply modules RPS17 are field replaceable All other Brocade ICX 7250 power supply units PSUs are fixed and internal to the devices All the PSUs use a C14 inlet and connect to standard AC power NOTE The E...

Страница 104: ...s at nominal speed NOTE The Brocade ICX 7250 does not support 48 VDC input power Model name 100 VAC input 200 VAC input 48 VDC input Minimum number of power supplies Notes ICX 7250 24G 0 56 A 33 6 W 114 7 BTU hr 0 35 A 33 3 W 113 5 BTU hr N A 1 All ports down no optics or cables connected No Load traffic ICX 7250 24 0 71 A 42 6 W 145 4 BTU hr 0 41 A 39 0 W 132 9 BTU hr N A 1 All ports down no opti...

Страница 105: ...ass 3 15 4 W port ICX 7250 48 0 64 A 63 6 W 216 9 BTU hr 0 34 A 61 1 W 208 6 BTU hr N A 1 48 1 GbE and 8 10 GbE ports are linked UP ONLY 10 traffic ICX 7250 48P 9 23 A 920 0 W 3140 0 BTU hr 4 43 A 862 0 W 2942 1 BTU hr N A 1 48 1 GbE and 8 10 GbE ports are linked UP ONLY 10 traffic 100 PoE Load Class 3 15 4 W port Power consumption maximum configuration Maximum All ports fully configured with conn...

Страница 106: ... Port type Number of ports Description ICX 7250 24G GbE copper 24 RJ 45 10 100 1000 ports GbE optical 4 SFP uplink ports ICX 7250 24 GbE copper 24 RJ 45 10 100 1000 ports 10 GbE optical 8 Uplink or stacking SFP ports ICX 7250 24P GbE copper 24 RJ 45 10 100 1000 ports 10 GbE optical 8 Uplink or stacking SFP ports ICX 7250 48 GbE copper 48 RJ 45 10 100 1000 ports 10 GbE optical 8 Uplink or stacking ...

Страница 107: ...ark Immunity for Information Technology Equipment ICES 003 Canada Class A AS NZ 55022 Australia Class A VCCI Japan Class A EN 61000 3 2 EN 61000 3 3 EN 61000 6 1 Regulatory compliance safety CAN CSA C22 2 No 60950 UL 60950 EN 60825 Safety of Laser Products EN 60950 IEC 60950 Safety of Information Technology Equipment Regulatory compliance environmental 2014 35 EU and 2014 30 EU 2011 65 EU Restrict...

Страница 108: ...tion Evaluation Authorisation and Restriction of Chemicals EU REACH Section 1502 of the Dodd Frank Wall Street Reform and Consumer Protection Act of 2010 U S Conflict Minerals 30 2011 TT BCT Vietnam circular SJ T 11363 2006 Requirements for Concentration Limits for Certain Hazardous Substances in EIPs China SJ T 11364 2006 Marking for the Control of Pollution Caused by EIPs China Brocade ICX 7250 ...

Страница 109: ...ponents have been properly installed If one or more components appear to be malfunctioning such as the power cord or network cabling test them in an alternate environment where you are sure that all the other components are functioning properly Power and cooling problems If the power indicator does not turn on when the power cord is plugged in you may have a problem with the power outlet power cor...

Страница 110: ...h which you are connecting to the device has not been disabled If it has not been disabled then check the network cabling that runs between your remote location and the device Troubleshooting Brocade ICX 7250 Switch Hardware Installation Guide 110 53 1003898 02 ...

Страница 111: ... CE mark which indicates that this system conforms to the provisions of the following European Council directives laws and standards Electromagnetic Compatibility EMC Directive 2004 108 EEC Low Voltage Directive LVD 2006 95 EC EN50082 2 EN55024 1998 European Immunity Requirements EN61000 3 2 JEIDA European and Japanese Harmonics Spec EN61000 3 3 China ROHS Refer to the latest revision of the China...

Страница 112: ...e de la classe A est conforme à la norme NMB 003 du Canada China CC statement Europe and Australia CISPR 22 Class A Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Regulatory Statements Brocade ICX 7250 Switch Hardware Installation Guide 112 53 1003898 02 ...

Страница 113: ...nt Machine noise information regulation 3 GPSGV the highest sound pressure level value is 70 0 dB A in accordance with EN ISO 7779 Maschinenlärminformations Verordnung 3 GPSGV der höchste Schalldruckpegel beträgt 70 0 dB A gemäss EN ISO 7779 KCC statement Republic of Korea Class A device Broadcasting Communication Device for Office Use This device obtained EMC registration for office use Class A a...

Страница 114: ...Regulatory Statements Brocade ICX 7250 Switch Hardware Installation Guide 114 53 1003898 02 ...

Страница 115: ...nstrumento en un entorno en el que la temperatura ambiente de operación pueda exceder los 50 C 122 F CAUTION Make sure the airflow around the front sides and back of the device is not restricted VORSICHT Stellen Sie sicher dass an der Vorderseite den Seiten und an der Rückseite der Luftstrom nicht behindert wird MISE EN GARDE Vérifiez que rien ne restreint la circulation d air devant derrière et s...

Страница 116: ... la commande write memory pour enregistrer la configuration actuelle dans le fichier startup config PRECAUCIÓN Use el comando erase startup config borrar configuración de inicio para sistemas nuevos solamente Si usted introduce este comando en un sistema que ya ha configurado el comando borrará la configuración Si usted borra accidentalmente la configuración en un sistema ya configurado introduzca...

Страница 117: ...nd fan assembly voids the warranty and regulatory certifications There are no user serviceable parts inside the power supply and fan assembly VORSICHT Das Zerlegen von Netzteilen oder Lüftereinheiten macht die Garantie und die gesetzlichen Zertifizierungen ungültig Die Netzteile und Lüftereinheiten enthalten keine Teile die vom Benutzer gewartet werden können MISE EN GARDE Le démontage d une pièce...

Страница 118: ...tibles Electrical dangers DANGER Before beginning the installation see the precautions in Power precautions GEFAHR Vor der Installation siehe Vorsichtsmaßnahmen unter Power Precautions Vorsichtsmaßnahmen in Bezug auf elektrische Ablagen DANGER Avant de commencer l installation consultez les précautions décrites dans Power Precautions Précautions quant à l alimentation PELIGRO Antes de comenzar la ...

Страница 119: ...ured to prevent it from becoming unstable or falling over GEFAHR Stellen Sie sicher dass das Gestell für die Unterbringung des Geräts auf angemessene Weise gesichert ist so dass das Gestell oder der Schrank nicht wackeln oder umfallen kann DANGER Vérifiez que le bâti abritant le dispositif est bien fixé afin qu il ne devienne pas instable ou qu il ne risque pas de tomber PELIGRO Verifique que el b...