FIGURE 11 Attaching the adhesive feet
1.
Attach the four adhesive feet to the bottom of the device. If installing multiple devices, attach the adhesive feet to each device.
2. Set the device on a flat desktop, table, or shelf near an AC power source. Make sure that adequate ventilation is provided for the
system. A 7.62 cm (3 in.) clearance is recommended on each side.
3. If installing a single device only, proceed to
on page 76. If installing multiple devices, place each
device squarely on top of the one below.
Installing the device into a rack
This section describes the procedures you use to mount the device into a rack.
The Brocade ICX 7250 can be installed in a 2-post or 4-post rack.
The device ships with a 2-post rack. To use the rack that ships with the product, refer to
Installing the device using the included two-post
on page 28.
To install the product into a four-post rack, you can order one of two four-post rack kits with the part number XBR-R000295 or
XBR-000296. For the procedures to install these kits, refer to
Installing the 1U, 1.5U, and 2U Universal Kit for Four Post Racks (XBR-
Installing the Universal Four-Post Rack Kit (XBR-R000296)
on page 43.
Installation
Brocade ICX 7250 Switch Hardware Installation Guide
53-1003898-02
27
Содержание ICX 7250
Страница 10: ...Preface Brocade ICX 7250 Switch Hardware Installation Guide 10 53 1003898 02 ...
Страница 12: ...About This Document Brocade ICX 7250 Switch Hardware Installation Guide 12 53 1003898 02 ...
Страница 22: ...Overview Brocade ICX 7250 Switch Hardware Installation Guide 22 53 1003898 02 ...
Страница 80: ...Installing the EPS4000 Brocade ICX 7250 Switch Hardware Installation Guide 80 53 1003898 02 ...
Страница 92: ...Configuring the Device Brocade ICX 7250 Switch Hardware Installation Guide 92 53 1003898 02 ...
Страница 114: ...Regulatory Statements Brocade ICX 7250 Switch Hardware Installation Guide 114 53 1003898 02 ...