Fig.11-18:
Overview on the circle test
Test execution
Precondition: The machine has to be in Automatic mode!
1.
Select axes.
2.
Determine rotational direction, feed, circle center and diameter.
3.
Start circle test with <F2>.
The necessary NC program is generated and loaded automatically.
4.
After the circle test has been started, the NC program has to be started.
5.
The test is executed automatically. After the result has been displayed,
either the analysis can be executed or the test can be restarted.
For a better evaluation, it can be zoomed within the circle diagram. Therefore,
click on the left mouse button in the left upper corner and drag it to the lower
right while keeping the button pressed. To see the complete curve again, press
<F7 Header zoom> and then <F8 Zoom 1:1>
Changing scaling
To show the deviation of the actual curve from the command curve, this devi‐
ation is displayed too high. To obtain an impression of the qualitative deviation,
so-called scaling rings drawn with an adjustable distance (scaling) are inserted.
If this scaling is modified, the curve is recalculated and then redrawn. The curve
is always displayed in such a manner that all measuring values are located
within the screen area. This results in a relatively large scaling in case of large
deviations.
The result can be documented via <F6 Print result>.
The following possibilities are available as F-key on the result page:
<F2>
Start and stop measurement.
<F3>
Load measurement
It loads a completed measurement with all settings related to
axis selection, feed and radius.
<F4>
Save measurement
Bosch Rexroth AG
DOK-MTX***-NC*OP***V11-AP01-EN-P
Rexroth IndraMotion MTX 11VRS Standard NC Operation
256/301
Extended Functionality
Содержание Rexroth IndraMotion MTX 11 VRS
Страница 1: ...Electric Drives and Controls Pneumatics Service Linear Motion and Assembly Technologies Hydraulics ...
Страница 14: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 12 301 ...
Страница 26: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 24 301 ...
Страница 36: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 34 301 ...
Страница 76: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 74 301 ...
Страница 114: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 112 301 ...
Страница 160: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 158 301 ...
Страница 290: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 288 301 ...
Страница 294: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 292 301 ...
Страница 303: ...Notes DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation Bosch Rexroth AG 301 301 ...