11.1.4
Operating Principle of the NC-Analyzer
General
The following summary shows the operating principle when working with the
NC-Analyzer:
Con.
no.
Procedure
1
Selecting a program
2
Starting the NC-Analyzer
3
Loading configuration file (optional)
4
Selecting channel (optional)
5
Navigating to the incorrect program part or to the subroutine in the NC-Ana‐
lyzer if required
6
Setting breakpoints at possible error locations
7
Selecting variables for monitoring
8
Starting NC program
9
Monitoring the values of the selected variables and the error analysis
10
Error clearance of the respective program parts in the control editor
11
Testing the program regarding error recovery.
... and whether more errors are present
12
Saving configuration (settings) or any subsequent NC-Analyzer sessions
Selecting the Program
The program selection is opened via the OP-key "Machine" of <F2>. Select the
NC program to be run.
●
Only one program can be edited at a time.
●
To edit a program, the file attribute of the program needs to be configured
accordingly. In the "File" window, each file is prefixed with a symbol for
the file attribute.
●
The program displayed in the NC-Analyzer can only be edited there if it is
active in the selected control and the set channel.
●
If the selected program is edited in the control, all changes also become
active immediately in the NC-Analyzer (incl. monitored variables and sub‐
routines).
Loss of data!
●
If a different program is selected for processing, this is also
loaded into the NC-Analyzer at the same time. Changes in the
previous program will be lost.
●
The command "Reset channel" in the control means that
breakpoints and monitored variables are lost.
Channel Selection
The F-key <F2 channel selection> can be used to switch the channel in the NC-
Analyzer.
DOK-MTX***-NC*OP***V11-AP01-EN-P
Rexroth IndraMotion MTX 11VRS Standard NC Operation
Bosch Rexroth AG
233/301
Extended Functionality
Содержание Rexroth IndraMotion MTX 11 VRS
Страница 1: ...Electric Drives and Controls Pneumatics Service Linear Motion and Assembly Technologies Hydraulics ...
Страница 14: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 12 301 ...
Страница 26: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 24 301 ...
Страница 36: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 34 301 ...
Страница 76: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 74 301 ...
Страница 114: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 112 301 ...
Страница 160: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 158 301 ...
Страница 290: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 288 301 ...
Страница 294: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 292 301 ...
Страница 303: ...Notes DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation Bosch Rexroth AG 301 301 ...