Here, one or more file extensions can be specified for which syntax high‐
lighting is used. The following extensions have been entered already:
"npg", "cpl", "dat", "txt" and files without file extension. Others can be add‐
ed; these can also be removed again. By default, file extensions "npg" and
"cpl" are shown with syntax highlighting.
7.2.7
GNP Correction Function
This function is available only if you have a license for GNP.
It retrieves the correction of a GNP instruction. This command opens its own
dialog which covers that of the NC Editor.
7.2.8
Text Editor
The text editor is retrieved for large programs (default >1 MB). The options for
the text editor can be set using the F-keys under "Tools/Options/Adjust". In
doing so, general text editor settings can be made or the editor can be activated
depending on the file size. The text editor's performance is better.
It does not have the following functions:
●
Graphic GNP NC programming
●
Syntax highlighting
●
No continuous automatic block numbering
●
Limited renumbering of NC programs
When NC programs are renumbered, jumps to block numbers are not de‐
tected. All NC blocks are renumbered.
●
Error handling
The error handling is restricted. The faulty parts of the program are marked
but not highlighted after opening the editor and when navigating to the
next/previous error. The change records of the document result in an up‐
date in the error list of the editor (no error deletion after modification of the
faulty line, no displacement of the error position after inserting/deleting
complete lines in front of a faulty line.
All other functions can be used.
7.2.9
Online Help: NC Programming Instructions
The online help for the DIN programming instructions is retrieved using <F1>.
7.2.10
Interruption of the Connection
If the connection to the control system is interrupted, all NC Editors are closed.
If edited data has not been saved at this point in time, the files are saved on
the hard disk under the same name (including the path) in the directory "c:
\SaveXXXXXXXX". XXXXXXXX stands for the abbreviation of the current date
(year/month/day).
Example:
Save20050614 corresponds to the 14th of June 2005. After the connection has
been restored, the saved files can be copied to a mount directory of the control
system with the help of the Windows Explorer.
Bosch Rexroth AG
DOK-MTX***-NC*OP***V11-AP01-EN-P
Rexroth IndraMotion MTX 11VRS Standard NC Operation
124/301
Programming
Содержание Rexroth IndraMotion MTX 11 VRS
Страница 1: ...Electric Drives and Controls Pneumatics Service Linear Motion and Assembly Technologies Hydraulics ...
Страница 14: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 12 301 ...
Страница 26: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 24 301 ...
Страница 36: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 34 301 ...
Страница 76: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 74 301 ...
Страница 114: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 112 301 ...
Страница 160: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 158 301 ...
Страница 290: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 288 301 ...
Страница 294: ...Bosch Rexroth AG DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation 292 301 ...
Страница 303: ...Notes DOK MTX NC OP V11 AP01 EN P Rexroth IndraMotion MTX 11VRS Standard NC Operation Bosch Rexroth AG 301 301 ...