12.4.8
0x3007/0 Percentage actual value 1
Index Sub-index
Meaning
Data type Access Map Def.-Val
0x3007
0
Percentage actual value 1
Unsigned16
ro
Tx
Object 0x3007 displays the value of a percentage source which is selectable via pa-
rameter
CANopen
®
Percentage Actual Value Source
1423.
Default source is 52 – Analog Input MFI1A.
The percentage value is scaled as percent * 100 (e.g. 5678 represents 56.78%).
Example:
COB ID CB Index SI Data
Read Request
601
40 07 30 00 00 00
Reply
581
4B 07 30 00 8F 13
CB: Control byte SI: Sub Index All values in hexadecimal without leading 0x