Status word
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit
0
Ready to switch on
1
Switched on
2
Operation enabled
3
Fault
4
Voltage enabled
5
Quick stop (Low Active)
6
Switch on disabled
7
Warning
8
-
9
Remote
10
Target reached
11
Internal limit active
12
Homing attained
13
Homing error
14
-
15
Warning 2
Control w ord
Name
Value
Description
Homing op-
eration start
Bit 4
0
Homing mode inactive
0
1 Start homing mode
1
Homing mode active
1
0 Interrupt homing mode
Halt
Bit 8
0
Execute instruction of bit 4 “homing operation start”
1
Stop axle with homing acceleration, , inverter remains in
state “operation enabled”