12.4.4
0x3003/0 Digital Out set values
Index Sub-index
Meaning
Data type Access Map Def.-Val
0x3003
0
Digital Out set values
Unsigned8
rw
Rx
0
Via object 0x3003 there are 5 digital sources available for use with parameters, which
require digital values.
Object 0x3003
Bit
Source no.
Source name
Operation mode
Digital output
0
810
Obj 0x3003 Digout 1
90/190
1
811
Obj 0x3003 Digout 2
91/191
2
812
Obj 0x3003 Digout 3
92/192
3
813
Obj 0x3003 Digout 4
93/193
4
814
Obj 0x3003 Digout 5
94/194
The value of object 0x3003 is limited from 0 to 31.
No.
Object
Min.
Max.
0x3003/0 Digital Out set values
0
31 (= 0x1F)
Digital outputs use these sources as operation mode 90 … 94
Obj 0x3003 DigOut
1 … 5 respectively inverted as 190 ... 194 inv. Obj 0x3003 DigOut 1 … 5 (see e.g.
parameter
Op. Mode Digital Output 1
530). The mapping of this object bits to the
outputs is arbitrary.
Example:
Function
Parameter no.
Choice list (excerpt)
Op. Mode Digi-
tal Output 3
532
0 - OFF
1 - Ready or Standby Signal
2 - Run Signal
…
43 - External Fan
90 - Obj 0x3003 Digout 1
91 - Obj 0x3003 Digout 2
92 - Obj 0x3003 Digout 3
93 - Obj 0x3003 Digout 4
94 - Obj 0x3003 Digout 5
…
143 - inv. External Fan
190 - inv. Obj 0x3003 Digout 1
191 - inv. Obj 0x3003 Digout 2
192 - inv. Obj 0x3003 Digout 3
193 - inv. Obj 0x3003 Digout 4
194 - inv. Obj 0x3003 Digout 5
…
The sources can be chosen directly by the selection of 810…814
Obj 0x3003 DigOut
1 … 5 from the parameters choice list. This can be used e.g. for direct setting of Bool-
ean inputs.
Example:
COB ID CB Index SI Data
Read Request
601
40 03 30 00 00
Reply
581
4F 03 30 00 03
Write Access
601
2F 03 30 00 10
Reply
581
60 03 30 00 00
CB: Control byte SI: Sub Index All values in hexadecimal without leading 0x
04/13
CM-CAN ACU
87