The synchronization of several drives needs high refresh rates to assure optimum
results. Set the corresponding time (i.e.
TxPDO1 Time
931) at the transmit side to
a low value. For the usage of the sync-function at the system bus set
SYNC-Time
919 to a low value.
The bus load of the system bus must have sufficient reserves for proper operation.
The system bus is described in the manuals of the extension modules with system
bus interface.
Block diagram: electronic gear and phasing function
The master position and speed is multiplied with the
gear factor. When a Phasing is
started, the Phasing profile is added to the Master Speed until the Phasing offset is
reached.
The
gear factor is defined by the following Objects or parameters:
Object
Parameter
0x5F10/1 Gear factor Numerator
1123
Gear Factor Numerator
0x5F10/2 Gear factor Denominator
1124
Gear Factor Denominator
0x5F10/3 Gear factor Resync on change 1142
Resync. on Change of Gear-Factor
The
Phasing is defined by the following Objects or parameters:
Object
Parameter
Phasing 1: Offset
Phasing 2: Offset
Phasing 3: Offset
Phasing 4: Offset
1125.1
1125.2
1125.3
1125.4
Phasing: Offset
Phasing 1: Speed
Phasing 2: Speed
Phasing 3: Speed
Phasing 4: Speed
1126.1
1126.2
1126.3
1126.4
Phasing: Speed
Phasing 1: Acceleration
Phasing 2: Acceleration
Phasing 3: Acceleration
Phasing 4: Acceleration
1127.1
1127.2
1127.3
1127.4
Phasing: Acceleration