Configuration Mode (ConF)
227
Code
Nam e / De s cription
Adjus tment range
Factory s e tting
FUn-
[APPLICATION FUNCT.]
(continued)
LPO-
[POSITIONING BY SENSORS]
Note :
This function cannot be used w ith certain other functions. Follow the instructions on page
163
.
SAF
nO
LI1
...
[Stop FW limit sw.]
[No]
(nO)
Stop sw itch forward.
[No]
(nO)
: Not assigned
[LI1]
(LI1)
: Logical input LI1
[...]
(...)
: See the assignment conditions on page
153
SAr
[Stop RV limit sw.]
[No]
(nO)
Stop sw itch reverse.
Identical to
[Stop FW lim it s w .]
(SAF)
above.
SAL
*
LO
HIG
[Stop limit config.]
[Active low ]
(LO)
WARNING
LOSS OF CONTROL
If
[Stop limit config.]
(SAL)
is s et to
[Active high]
(HIG)
, the s top com m and will be activated on active
s ignal and the s top com m and will not be applied if the connection is rem oved.
Verify that us ing this s etting does not res ult in uns afe conditions.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
Stop sw itch activation level.
This parameter can be accessed if at least one limit sw itch or one stop sensor has been assigned. It defines the positive or
negative logic of the bits or inputs assigned to the stop.
[Active low]
(LO)
: Stop controlled on a falling edge (change from 1 to 0) of the assigned bits or inputs
[Active high]
(HIG)
: Stop controlled on a rising edge (change from 0 to 1) of the assigned bits or inputs
dAF
[Slowdown forward]
[No]
(nO)
Slow down attained forward.
Identical to
[Stop FW lim it s w .]
(SAF)
above.
dAr
[Slowdown reverse]
[No]
(nO)
Slow down attained reverse.
Identical to
[Stop FW lim it s w .]
(SAF)
above.
dAL
*
LO
HIG
[Slowdown limit cfg.]
[Active low ]
(LO)
WARNING
LOSS OF CONTROL
If
[Slowdow n limit cfg.]
(dAL)
is s et to
[Active high]
(HIG)
, the s lowdown com m and will be activated on
active s ignal and the s lowdown com m and will not be applied if the connection is rem oved.
Verify that us ing this s etting does not res ult in uns afe conditions.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
This parameter can be accessed if at least one limit sw itch or one slowdown sensor has been assigned. It defines the positive
or negative logic of the bits or inputs assigned to the slow down.
[Active low]
(LO)
: Slowdown controlled on a falling edge (change from 1 to 0) of the assigned bits or inputs
[Active high]
(HIG)
: Slow dow n controlled on a rising edge (change from 0 to 1) of the assigned bits or inputs
Parameters described in this page can be accessed by:
DRI- > CONF > FULL > FUN- > LPO-
Содержание ER24 Series
Страница 1: ...BLEMO ER24 Variable Speed Drives for Asynchronous and Synchronous Motors Programming Manual 05 2018 ...
Страница 6: ...6 Table of Contents ...
Страница 14: ...16 ...
Страница 34: ...Overview 36 ...
Страница 40: ...42 ...
Страница 74: ...Monitoring Mode MOn 76 ...
Страница 241: ......
Страница 278: ...Configuration Mode ConF 278 Access Level See Access Level LAC page 280 ...
Страница 294: ...Interface ItF 294 ...
Страница 298: ...298 Open Save as trA ...
Страница 302: ...Multipoint Screen 302 ...
Страница 304: ...304 ...
Страница 306: ...Maintenance 306 ...
Страница 316: ...Diagnostics and Troubleshooting 316 ...
Страница 318: ...318 ...
Страница 340: ...Index of Parameter Codes 340 ...
Страница 343: ......
Страница 344: ...Index of Parameter Codes 342 ER24_Programming_Manual_EN_01 2017 ...