Configuration Mode (ConF)
190
Code
Nam e / De s cription
Adjus tment range
Factory s e tting
ASt
[Angle setting type]
[PSIO align.]
(PSIO)
*
Mode for measuring the phase-s hift angle. Visible only if
[Mot or control type]
(Ctt)
is set to
[Sync. mot.]
(SYn)
.
[PSI align]
(PSI)
and
[PSIO align]
(PSIO)
are w orking for all type of synchronous motors.
[SPM align]
(SPMA)
and
[IPM align]
(IPMA)
increase performances depending on the type of synchronous motor.
[IPM align]
(IPMA)
: Alignment for IPM motor. Alignment mode for Interior-buried Permanent Magnet motor (usually, this kind
of motor has a high saliency level). It uses high frequency injection, w hich is less noisy than standard alignment mode.
[SPM align]
(SPMA)
: Alignment for SPM motor. Mode for Surface-mounted Permanent Magnet motor (usually, this kind of
motor has a medium or low saliency level). It uses high frequency injection, w hich is less noisy than standard alignment mode.
[PSI align]
(PSI)
: Pulse signal injection. Standard alignment mode by pulse signal injection.
[PSIO align]
(PSIO)
: Pulse signal injection - Optimized. Standard optimized alignment mode by pulse signal injection. The
phase-shift angle measurement time is reduced after the first run order or tune operation, even if the drive has been turned off.
[No align]
(nO)
: No alignment
IPMA
SPMA
PSI
PSIO
nO
(1) The parameter can also be accessed in the
[SETTINGS]
(SEt-)
menu.
These parameters only appear if the corresponding function has been selected in another menu. When the parameters can
also be accessed and adjusted from w ithin the configuration menu for the corresponding function, their description is detailed
in these menus, on the pages indicated, to aid programming.
Parameter that can be modified during operation or w hen stopped.
To change the assignment of this parameter, press the ENT key for 2 s.
2 s
*
Содержание ER24 Series
Страница 1: ...BLEMO ER24 Variable Speed Drives for Asynchronous and Synchronous Motors Programming Manual 05 2018 ...
Страница 6: ...6 Table of Contents ...
Страница 14: ...16 ...
Страница 34: ...Overview 36 ...
Страница 40: ...42 ...
Страница 74: ...Monitoring Mode MOn 76 ...
Страница 241: ......
Страница 278: ...Configuration Mode ConF 278 Access Level See Access Level LAC page 280 ...
Страница 294: ...Interface ItF 294 ...
Страница 298: ...298 Open Save as trA ...
Страница 302: ...Multipoint Screen 302 ...
Страница 304: ...304 ...
Страница 306: ...Maintenance 306 ...
Страница 316: ...Diagnostics and Troubleshooting 316 ...
Страница 318: ...318 ...
Страница 340: ...Index of Parameter Codes 340 ...
Страница 343: ......
Страница 344: ...Index of Parameter Codes 342 ER24_Programming_Manual_EN_01 2017 ...