Configuration Mode (ConF)
225
Example: Forward slowdown, on rising edge
•
Forward s lowdown takes place on a ris ing edge (change from 0 to 1) of the input or bit as s igned to forward
s lowdown if this ris ing edge occurs in forward operation. The s lowdown com mand is then s tored, even in
the event of a power outage. Operation in the oppos ite direction is authorized at high s peed. The s lowdown
com m and is deleted on a falling edge (change from 1 to 0) of the input or bit as s igned to forward s lowdown
if this falling edge occurs in revers e operation.
•
A bit or a logic input can be as s igned to dis able this function.
•
Although forward s lowdown is disabled while the disable input or bit is at 1, s ens or changes continue to be
m onitored and s aved.
Example: Positioning on a limit switch, on rising edge
Operation with short cams:
In this ins tance, when operating for the firs t tim e or after res toring the factory s ettings , the drive m us t initially
be s tarted outs ide the s lowdown and s top zones in order to initialize the function.
Forw ard slow dow n zone
Forw ard slow dow n
Forw ard stop zone
Forw ard stop
Parameters described in this page can be accessed by:
DRI- > CONF > FULL > FUN- > LPO-
stop
Reverse
Reverse
Forw ard
stop
WARNING
LOSS OF CONTROL
Verify correct connection of the limit switches.
Verify the correct installation of the limit switches. The limit switches must be mounted in a position far
enough away from the mechanical stop to allow for an adequate stopping distance.
You must release the limit switches before you can use them.
Verify the correct function of the limit switches
Failure to follow these instructions can result in death, serious injury, or equipment damage.
WARNING
LOSS OF CONTROL
When operating for the first time or after a reset of the configuration to the factory settings, the motor must
always be started outside of the Slowdown and Stop ranges.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
WARNING
LOSS OF CONTROL
When the drive is switched off, it stores the range which it is currently in.
If the system is moved manually while the drive is off, you must restore the original position before switching
it on again.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
Содержание ER24 Series
Страница 1: ...BLEMO ER24 Variable Speed Drives for Asynchronous and Synchronous Motors Programming Manual 05 2018 ...
Страница 6: ...6 Table of Contents ...
Страница 14: ...16 ...
Страница 34: ...Overview 36 ...
Страница 40: ...42 ...
Страница 74: ...Monitoring Mode MOn 76 ...
Страница 241: ......
Страница 278: ...Configuration Mode ConF 278 Access Level See Access Level LAC page 280 ...
Страница 294: ...Interface ItF 294 ...
Страница 298: ...298 Open Save as trA ...
Страница 302: ...Multipoint Screen 302 ...
Страница 304: ...304 ...
Страница 306: ...Maintenance 306 ...
Страница 316: ...Diagnostics and Troubleshooting 316 ...
Страница 318: ...318 ...
Страница 340: ...Index of Parameter Codes 340 ...
Страница 343: ......
Страница 344: ...Index of Parameter Codes 342 ER24_Programming_Manual_EN_01 2017 ...