Configuration Mode (ConF)
200
Code
Nam e / De s cription
Adjus tment range
Factory s e tting
FUn-
[APPLICATION FUNCT.]
(continued)
ELM-
[EXTERNAL WEIGHT MEAS.]
PES
nO
A11
A12
A13
PI
AIU1
AIU2
OA01
...
OA10
[Weight sensor ass.]
[No]
(nO)
WARNING
LOSS OF CONTROL
•
Verify that
[Point 1 X]
(LP1)
,
[Point 2x]
(LP2)
,
[Point 1Y]
(CP1)
and
[Point 2Y]
(CP2)
are correctly
s et to avoid los s of control of the load being lifted.
•
Perform a com prehensive com missioning tes t to confirm the value given to the param eters
[Point 1 X]
(LP1)
,
[Point 2x]
(LP2)
,
[Point 1Y]
(CP1)
and
[Point 2Y]
(CP2)
.
Failure to follow these instructions can result in death, serious injury, or equipment damage.
This parameter can be configured if
[BRAK E LOGIC CONTR O L]
(bLC-)
page
194
is not set to
[No]
(nO)
.
[No]
(nO)
: Not assigned
[Al1]
(A11)
: Analog input A1
[Al2]
(A12)
: Analog input A2
[Al3]
(A13)
: Analog input A3
[RP]
(PI)
: Pulse input
[AI virtual 1]
(AIU1)
: Virtual analog input 1 w ith the jog dial
[AI virtual 2]
(AIU2)
: Virtual analog input 2 by the communication bus
[OA01]
(OA01)
: Function blocks: Analog Output 01
...
[OA10]
(OA10)
: Function blocks: Analog Output 10
LP1
*
[Point 1 X]
0 to LP2-0.01%
0%
0 to 99.99% of signal on assigned input.
[Point 1x]
(LP1)
must be less than
[Point 2x]
(LP2)
.
This parameter can be accessed if
[We ight s ensor as s.]
(PES)
is assigned.
CP1
*
[Point 1Y]
-1.36 In to 1.36 In (1)
-In (1)
Current corresponding to load
[Point 1 X]
(LP1)
, in A.
This parameter can be accessed if
[We ight s ensor as s.]
(PES)
is assigned.
LP2
*
[Point 2X]
LP1+0.01% to 100%
50%
0.01 to 100% of signal on assigned input.
[Point 2x]
(LP2)
must be greater than
[Point 1x]
(LP1)
.
This parameter can be accessed if
[We ight s ensor as s.]
(PES)
is assigned.
CP2
*
[Point 2Y]
-1.36 In to 1.36 In (1)
0 A
Current corresponding to load
[Point 2x]
(LP2)
, in A.
This parameter can be accessed if
[We ight s ensor as s.]
(PES)
is assigned.
IbrA
*
[Ibr 4-20 mA loss]
0 to 1.36 In (1)
0
Brake release current in the event of the loss of the w eight sensor information.
This parameter can be accessed if the weight sensor is assigned to an analog current input and the 4-20 mA loss is deactivated.
Recommended settings: Rated motor current for a hoisting application.
(1) In corresponds to the rated drive current indicated in the Installation manual and on the drive nameplate.
These parameters only appear if the corresponding function has been selected in another menu. When the parameters can
also be accessed and adjusted from w ithin the configuration menu for the corresponding function, their description is detailed
in these menus, on the pages indicated, to aid programming.
Parameter that can be modified during operation or w hen stopped.
*
Содержание ER24 Series
Страница 1: ...BLEMO ER24 Variable Speed Drives for Asynchronous and Synchronous Motors Programming Manual 05 2018 ...
Страница 6: ...6 Table of Contents ...
Страница 14: ...16 ...
Страница 34: ...Overview 36 ...
Страница 40: ...42 ...
Страница 74: ...Monitoring Mode MOn 76 ...
Страница 241: ......
Страница 278: ...Configuration Mode ConF 278 Access Level See Access Level LAC page 280 ...
Страница 294: ...Interface ItF 294 ...
Страница 298: ...298 Open Save as trA ...
Страница 302: ...Multipoint Screen 302 ...
Страница 304: ...304 ...
Страница 306: ...Maintenance 306 ...
Страница 316: ...Diagnostics and Troubleshooting 316 ...
Страница 318: ...318 ...
Страница 340: ...Index of Parameter Codes 340 ...
Страница 343: ......
Страница 344: ...Index of Parameter Codes 342 ER24_Programming_Manual_EN_01 2017 ...