LS 13 320 Specifications
Specifications
Only values with tolerances or limits are guaranteed data. Values without tolerances are informative data,
without guarantee.
Item
Specification
Power
100 ±10 V, 120 ±10 V, 220 ±20 V, or 240 ±20 V
50/60 Hz
£
6 A
Temperature
10° to 40° C (50° to 104° F)
IMPORTANT
If room temperature varies 2° C/hour, perform alignment and offsets tests more
often, at least once an hour.
Humidity
0 to 90% without condensation
Dimensions
Unit
Height
Width
Depth
Optical Module
44.5 cm (17.5 in)
101 cm (40 in)
25.4 cm (10 in)
Computer Processor with Disk Drive
13 cm (5 in)
36 cm (14 in)
41 cm (16 in)
Monitor
32 cm (12.5 in)
32 cm (12.5 in)
41 cm (16 in)
Printer
23 cm (9 in)
39 cm (15.5 in)
41 cm (16 in)
Weight
71.5 lbs (32.5 kg)
Altitude
Sea level to 3,000 m (10,000 ft)
Laser
Classification
I for operator (no access to radiation)
IIIb for service and maintenance (trained Beckman Coulter personnel only).
Power
5 mW
4 mW operating power
Wavelength
750 nm or 780 nm
NOTE
750 nm laser has been discontinued
Life Expectancy
70,000 hours
Содержание LS 13 320
Страница 4: ...PN B05577AC iv Revision History ...
Страница 12: ...PN B05577AC xii Safety Notice Scope of Manual ...
Страница 30: ...PN B05577AC xxx LS 13 320 Introduction System Components ...
Страница 57: ...PN B05577AC 2 21 Installation Making Measurements 2 Figure 2 18 Run Cycle Options Dialog ...
Страница 58: ...PN B05577AC 2 22 Installation Making Measurements Figure 2 19 Reference Background File Selection ...
Страница 59: ...PN B05577AC 3 1 CHAPTER 3 LS 13 320 Software Figure 3 1 LS 13 320 Software ...
Страница 80: ...PN B05577AC 3 22 LS 13 320 Software Preference Options ...
Страница 86: ...PN B05577AC 3 28 LS 13 320 Software Preference Options ...
Страница 105: ...PN B05577AC 3 47 LS 13 320 Software High Security 3 Figure 3 5 User Privileges Dialog High Security ...
Страница 116: ...PN B05577AC 4 10 Regulatory Compliance 21 CFR Part 11 Starting Security Enabled Software ...
Страница 118: ...PN B05577AC 5 2 Data File Menus RunFile Menu 3 Select the file you wish to overlay with the current opened file 4 Open ...
Страница 169: ...PN B05577AC 6 39 Sample Modules Micro Liquid Module 6 Figure 6 27 SOM List Dialog ...
Страница 216: ...PN B05577AC 6 86 Sample Modules Universal Liquid Module ...
Страница 228: ...PN B05577AC B 10 Sample Handling Diluent Selection ...
Страница 238: ...PN B05577AC C 10 Optical Models Statistics ...
Страница 252: ...PN B05577AC Warranty 2 Beckman Coulter Inc Customer End User License Agreement ...
Страница 253: ......