Tab.17 Flue gas system connection type B23p
Arrangement
Configuration
Unit
POWER HT+
1.50
POWER HT+
1.70
POWER HT+
1.90
POWER HT+ 1.110
mm
Ø 80
Ø 110 Ø 80
Ø 110
Ø 110
Ø 125
Ø 110
Ø 125 Ø 160
L3<2m + 2 el
bows
(L1 + L2) rigid m
20
56
8
56
20
56
56
56
–
L3<2m + 2 el
bows
(L1 + L2) flexi
ble
m
15
56
6
38
–
21
15
–
–
L3<5m + 2 el
bows
(L1 + L2) rigid m
–
56
–
56
24
56
–
43
56
L3<5m + 2 el
bows
(L1 + L2) flexi
ble
m
–
56
–
38
13
–
–
–
–
Pressure available at blow back Pa
200
200
200
200
Ventilation of the premises: In accordance with the standard NFP 45 –
204 or DTU 61.1
Lengths L1, L2 and L3 are obtained with Centrovec pipes covered by
CE marking and the TAD Technical Application Directive.
Fig.50 Maximum length of the connections
MW
-3000033
1
3
4
L
L
L1
L2
L
L
L
L
L
L
5
7
8
6
9
2
6 Installation
7609474 - v02 - 04092014
47