91
Trap
In case the alarm/error raise up, the Wolf 2MS sends a trap if <enable>.
If is <disable> no action are taken.
Label
This is the label/content that the user can choose to shows via email or in the trap in
case of error.
Note1
Condition
Description
Error Generation
Min. Threshold
If the RF Signal level under control < (
Min. Thr
) for a duration >
Validation
= the error is
generated
Error Come out
Min. Threshold
If the RF Signal level under control > (
Min. Thr + Hysteresis
) for a duration >
Hold
= the error
come out