Tested in scanning mode with another carrier to alternate the conditions.
F1=100.80MHZ ( Pilot sweeping from 4 kHz to 8kHz)
F2=100.50 MHZ (6.5 kHz stable)
Tested first as "multilevel alarm": PilotLow=Failure and PilotWindow=Out of Nominal Zone ;
PilotLowThr:5.0kHz, PilotThrMin:6.0kHz, PilotThrMax:7.0kHz Hyst: 0.3kHz, Validation:2sec, Hold:2Sec
PilotLowThr:5.0kHz, PilotThrMin:6.0kHz, PilotThrMax:7.0kHz Hyst: 0.3kHz, Validation:20sec, Hold:10Sec
PilotLowThr:5.0kHz, PilotThrMin:6.0kHz, PilotThrMax:7.0kHz Hyst: 0.3kHz, Validation:180sec, Hold:60Sec
Tested then as: PilotLow=LowThr and PilotWindow=MaxThr;
PilotLowThr:6.0kHz, PilotThrMin:0.0kHz, PilotThrMax:7.0kHz Hyst: 0.3kHz, Validation:2sec, Hold:2Sec
PilotLowThr:6.0kHz, PilotThrMin:0.0kHz, PilotThrMax:7.0kHz Hyst: 0.3kHz, Validation:20sec, Hold:10Sec
PilotLowThr:6.0kHz, PilotThrMin:0.0kHz, PilotThrMax:7.0kHz Hyst: 0.3kHz, Validation:180sec, Hold:60Sec
The behavior observed has been compatible with the specifications with the same static case accuracy error
In scanning mode all traps will be sent in the same way but the validation and hold time must be calculated on the time
the scanner is observing the channel.
The traps will be sent if the instant the alarm rises up, but the Pilot Level value and the time in the var-binds will be
related to the first sample out of the range.
Содержание WOLF 1MS
Страница 1: ...WOLF 1MS WOLF 2MS User Manual FM monitoring system and streaming device Rev 1 3...
Страница 10: ...ENG GENERAL DESCRIPTION 10...
Страница 11: ...ENG GENERAL DESCRIPTION 11...
Страница 12: ...ENG GENERAL DESCRIPTION 12...
Страница 14: ...ENG GENERAL DESCRIPTION 14 WOLF 1MS WEB PAGE...
Страница 15: ...ENG GENERAL DESCRIPTION 15 WOLF 2MS WEB PAGE...
Страница 16: ...ENG GENERAL DESCRIPTION 16 WOLF 1MS WOLF 2MS BLOCK DIAGRAM...
Страница 78: ...78 Example 3 RFL2 MASK This schemes shows from left to right the flow of each single Alarm...
Страница 216: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 216...
Страница 218: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 218...
Страница 221: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 221...