TECHNICAL APPENDIX
| TECHNICAL APPENDIX
185
16.11.14
RDS TA Data test (Tuner-1 Tuner-2)
This test checks alarms and traps on a Radio with TA=ON tuned on frequency 100.5MHz.
The test was carried out on both tuners.
System can check TA status and raise an alarm after a period of TA=ON (MaxOnTimeout) as can monitor TA status
invariance in time (alarm can be signaled after NoVarTimeout).
In Static mode we have set a TA MaxOnTimeout to 60 sec. and NoVarTimeout to 1440 min. (see fig. below)
Tuned radio TA=ON will raise up an alarm after MaxOnTimeout.
Under the alarm condition the RDS alarm led (we have associated the TA alarm to the panel led Rds error) on the panel
must be on (not flashing) and clicking on the channel number of the correspondent tuner the RDS error will be displayed
(“RDS DATA”).
Tested in Scan mode with 3 frequencies:
F1: 100.5 MHz
F2: 95.3 MHz
F3: 96.7 MHz
and MaxOnTimeout=60 sec.
– NoVarTimeout=1440 min. as depicted below.
In Scan Mode an alarm condition raises up after MaxOnTimeout time passed on channel 1.
Содержание WOLF 1MS
Страница 1: ...WOLF 1MS WOLF 2MS User Manual FM monitoring system and streaming device Rev 1 3...
Страница 10: ...ENG GENERAL DESCRIPTION 10...
Страница 11: ...ENG GENERAL DESCRIPTION 11...
Страница 12: ...ENG GENERAL DESCRIPTION 12...
Страница 14: ...ENG GENERAL DESCRIPTION 14 WOLF 1MS WEB PAGE...
Страница 15: ...ENG GENERAL DESCRIPTION 15 WOLF 2MS WEB PAGE...
Страница 16: ...ENG GENERAL DESCRIPTION 16 WOLF 1MS WOLF 2MS BLOCK DIAGRAM...
Страница 78: ...78 Example 3 RFL2 MASK This schemes shows from left to right the flow of each single Alarm...
Страница 216: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 216...
Страница 218: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 218...
Страница 221: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 221...