83
14.6.10
RFH1
This section is about the
Radio Frequency HIGHER LEVEL 1.
NAME
DESCRIPTION
NOTE
Chan (*)
Channel Number
Chan Label
Mnemonic name that can be applied to the Channel / Frequency
Frequency
Frequency corresponding to the Channel, expressed in MHz
Preset
String used and managed by the Configuration Manager
Scan Time
This value represents the time in seconds that the tuner remain on this frequency.
Chan Mask
This control allow (or not) the channel to be under control.
If it is masked,
the channel is
NOT under
control
Thr or Threshold
Threshold level.
Beyond
this threshold level an alarm is generated.
See Note1
reported
below
Hysteresis level
This value can be set as range of Hysteresis for the measurement. Hysteresis is the
dependence of a system not only on its current environment but also on its past
environment.
Validation
This field contains the time of persistence necessary to the alarm to be considered
“validated”. For example, if the system launches an alarm, this alarm must remain
“up” or “Active” for all the time of "Validation" to be considered a true alarm to avoid
the detection of spikes.
Hold
is the time between the cessation of the alarm condition and alarm signaling finished
Mask
It is possible to set, for each single parameter: unmasked, masked, severity-1,
severity-2, severity-3, RFL2 mask.
Email
In case the alarm/error raise up, the Wolf 2MS sends an email if <enable>.
If is <disable> no action are taken.
Trap
In case the alarm/error raise up, the Wolf 2MS sends a trap if <enable>.
If is <disable> no action are taken.
Label
This is the label/content that the user can choose to shows via email or in the trap in
case of error.
Содержание WOLF 1MS
Страница 1: ...WOLF 1MS WOLF 2MS User Manual FM monitoring system and streaming device Rev 1 3...
Страница 10: ...ENG GENERAL DESCRIPTION 10...
Страница 11: ...ENG GENERAL DESCRIPTION 11...
Страница 12: ...ENG GENERAL DESCRIPTION 12...
Страница 14: ...ENG GENERAL DESCRIPTION 14 WOLF 1MS WEB PAGE...
Страница 15: ...ENG GENERAL DESCRIPTION 15 WOLF 2MS WEB PAGE...
Страница 16: ...ENG GENERAL DESCRIPTION 16 WOLF 1MS WOLF 2MS BLOCK DIAGRAM...
Страница 78: ...78 Example 3 RFL2 MASK This schemes shows from left to right the flow of each single Alarm...
Страница 216: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 216...
Страница 218: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 218...
Страница 221: ...TECHNICAL APPENDIX TECHNICAL APPENDIX 221...