TECHNICAL APPENDIX
| TECHNICAL APPENDIX
176
SMART-WAIT timings:
CT: Max 130 seconds
(waits for a 4A, able to recognize an offset error or the failure of the service)
PS: Max 80 seconds
(waits a sequence of PS and able to recognize of up to 4 different PS or simply waits for PS variations)
RT: Max 80 seconds
(waits for A/B flag variations and/or groups 2A-2B presence)
TMC: Max 60 seconds
(waits for TMC service registration and/or TMC data variations)
RT+: Max 190 seconds
(waits for RT+ service registration and/or RT+ data variations)
IH: Max 190 seconds
(waits for IH data variations or service presence)
ODA1-2: Max 120 seconds
(waits for ODAx service registration and/or ODAx data variations)
RETRY SMART WAIT : 30 minutes (all services)
Actually these timings are fixed, but it planned in future to create a parameters group to adjust them.